Chapter 4 — ESim Commands
ESim for the PC4 and PF8 Printers Programmer’s Reference Manual 115
TS- Set Real-Time Clock
Purpose: Use this command to set the time and date in the optional real-time
clock circuit.
Syntax:
TSp
1
,p
2
,p
3
,p
4
,p
5
,p
6
.
Remarks: This command works only if the printer is fitted with an optional
real-time clock circuit (RTC).
Example:
This example sets the date to JAN 15,2004 and the time to 12:45:23
p.m.
TS01,15,04,12,45,23
U- Print Configuration (General)
Purpose: Use this command to print the current printer configuration on a
label without having to enter Dump mode.
Syntax: U
Example:
This example shows a typical label printed when using the U
command with the following setup:
Memory cartridge loaded
Media with black marks
Two forms, two graphics, and five soft fonts loaded
TS Command Parameter Descriptions
Parameter Description
p
1
Months are entered as 0-12.
p
2
Days are entered as 01-31.
p
3
Years are entered as the last two digits. For
example 2004 is entered as 04.
p
4
Hours entered in 24 hour format (00-23).
p
5
Minutes are entered as 00-59.
p
6
Seconds are entered as 00-59.