Chapter 4 — ESim Commands
ESim for the PC4 and PF8 Printers Programmer’s Reference Manual 99
The principles for how counters are printed by this example, where
the print command is P2,2.
Print Counters Example
PA - Print Automatic
Purpose: Use this command in a stored form sequence to automatically print
the form as soon as all variable data has been supplied.
Syntax: PAp
1
[,p
2
]
.
Remarks: Refer to the P command for explanations on how to print multiple
labels with counters. The PA command follows the same principles.
Counter: 1
Label No. 1
Counter: 1
Label No. 2
Counter: 2
Label No. 3
Counter: 2
Label No. 4
PA Command Parameter Descriptions
Parameter Description
p
1
Number of label sets (1-65535).
p
2
Number of copies of each label (1-64435) that
is used in combination with counters to print
multiple copies of the same label.