Chapter A — Error Handling
160 ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
Example:
Command eRF,6,N substitutes at error reply <XOFF> with the
character “F,” and at error recovery <XON> with the character “N.”
Error Response Tables
This table lists the error responses and codes reported when
Command US is on.
Error Responses and Codes Reported When Command US Is On
Error
Code
Error
Type
Description LED Serial
Response to
Command ^ee
No error GRN
01 A Syntax error RED <NAK>01[XOFF
]
01<CRLF>
02 B Object exceeds image
buffer border
ORA <NAK>02[XOFF
]
02<CRLF>
03 A Data length error RED <NAK>03[XOFF
]
03<CRLF>
04 A Insufficient memory
to store data
RED <NAK>04[XOFF
]
04<CRLF>
05 A Memory
configuration error
RED <NAK>05[XOFF
]
05<CRLF>
07 C Out of media, marked
with Pnnn = Number
of remaining labels.
RED <NAK>07[XOFF
]
07<CRLF>
08 A Form or image name
duplicate.
RED <NAK>08[XOFF
]
08<CRLF>
09 A Form or image not
found
RED <NAK>09[XOFF
]
09<CRLF>
11 D Printhead up (cover
open)
RED <NAK>11[XOFF
]
11<CRLF>
13 E LTS detection
waiting, peel pause.
- <NAK>13[XOFF
]
13<CRLF>
16 A No form was retrieved
before “?<CRLF>” was
entered.
RED <NAK>16[XOFF
]
16<CRLF>

Table of Contents