EasyManua.ls Logo

Intermec PC4

Intermec PC4
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 — ESim Commands
98 ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
.
Remarks: The oR command is a global printer command and:
cannot be issued inside a form.
must be issued prior to issuing a text command and printing it.
affects a single character on all code pages. Changing the character
position restores the original character.
flash memory printer parameter data is preserved until changed
by the oR command, or the printer is reset to default.
Example:
oRE
oRE,128
oR
P - Print
Purpose: Use this command to print the contents of the image buffer.
Syntax: Pp1[,p2]
Remarks: You cannot use the P command inside a stored form sequence. For
automatic printing of stored forms, use the PA command.
Example: This example prints two label sets of one label each, see the
command below:
P2,1
oR Command Parameter Descriptions
Parameter Description
p
1
If p
1
= E, the Euro character is mapped to the
code page position specified by p
2
. If no p
1
or
p
2
parameters are give, all code pages are reset
to the original default character mapping.
p
2
Specifies the code page position for the Euro
character in the range ASCII 32-255 decimal
for all code pages, provided p
1
= E. If p
2
is
omitted, the Euro character is mapped to the
code page position ASCII 213 decimal for all
code pages provided that p
1
= E.

Table of Contents

Related product manuals