PO
(261PO) Sand Filter Pump & Saltwater System with E.C.O. ENGLISH 7.5” X 10.3” PANTONE 295U 07/23/2014
English
SAVE THESE INSTRUCTIONS
Page 31
TROUBLESHOOTING GUIDE (continued)
INSUFFICIENT
CHLORINE
WHITEFLAKESIN
THEWATER
NOLEDDISPLAY
Without cyanuric acid.
•
Insufficient operating hours of
the Saltwater System.
•
The salt level in the pool water
is less than 2000ppm. This is
insufficient.
•
Chlorine loss due to intense
sunlight exposure.
•
The bather load has increased.
•
Clogged or dirty electrolytic cell.
• HighUVlevelexposure.
•
Excessive calcium hardness is
present in pool water.
Nopowersupply.
• RCD/GFCIhasnotreseted.
•
A power fuse has blown.
•
LED failure.
•
See “Cyanuric acid table”.
•
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
•
CheckthesaltlevelwiththeTestKit.
Adjust as needed. See “Salt & Pool Water
Volumes”.
Use a pool cover when the pool is not in use
and/or when the unit is operating.
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
Remove the cell for inspection, clean it if
necessary. See “Maintenance”.
• Coverthepoolwithapoolcoverfor2days
with the device running and then test the
waterusing the test strips.
• Ifthepooliscleanandclear,addstabilizer
to the water and then test the water.
Drainabout20to25%ofthepool
water and add fresh water to decrease
the calcium hardness. Inspect the
electrolytic cell for scale buildup. Clean
the electrolytic cell if necessary.
Plug the cell cord firmly into the cell
housing receptacle.
ResettheRCD/GFCI.
Contact Intex Service Center.
Contact Intex Service Center.
PROBLEM CAUSE SOLUTION