TROUBLESHOOTING GUIDE (continued)
1
. Circulation line is blocked.
2
. Incorrect inlet and outlet hose
direction.
3
. Scale on the flow sensor.
4
.Flowsensorcordisloose.
5
. Device is set and operating in
backwash, rinse or waste mode.
6
.Flowsensorfailure.
1
. Dirt or scale on titanium plates.
2
.Lowsaltlevel/Nosalt.
3
. Electrolytic cell cord is loose.
4
. Possible electrolytic cell failure.
1
.Highsaltlevel.
2
. Possible electrolytic cell failure.
1
. Display and all lights are off - the
system does not power up.
•
If your unit has plunger valves, ensure
that they are open.
•
Clear your basket and cell from
debris and dirt. See “Maintenance”.
•
Depress the 6-way valve,
r
elease all
trapped air in the circulation line.
•
Check the direction of the inlet and the
outlet hose. Reverse the hoses if
necessary. See “Set Up Instructions”.
•
Clean the flow sensor, paying special
attention to the hinge. See
“Maintenance”.
Plug the flow sensor firmly into the flow
sensor receptacle.
• Ignorethealarm,finishthebackwash,rinse
or waste operation then turn the power
switchOFFandONagaintoresetthealarm.
Contact Intex Service Center.
Remove the electrolytic cell for
inspection. Clean it if necessary.
See “Maintenance”.
Add salt. See “Salt & Pool Water
Volumes”.
Ensure that the cell cord is plugged
firmly into the cell housing receptacle.
Contact Intex Service Center. Replace
the cell if needed.
Partially drain the pool and refill it with
fresh water. See “Salt & Pool Water
Volumes”.
Contact Intex Service Center. Replace
the cell if needed.
Householdvoltageistoohighortoolow
(+20%).Checkthevoltageiswithinthe
range stated on the device housing.
Contact Intex Service Center.