EasyManua.ls Logo

Intex Krystal Clear SF90110T - Troubleshooting Guide

Intex Krystal Clear SF90110T
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
193
PO
SAVE THESE INSTRUCTIONS
(193PO) MODEL SF90110T SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
Page 20
TROUBLESHOOTING GUIDE
TROUBLE CAUSE SOLUTION
• Linecordmustbepluggedintoa3wireoutlet
thatisprotectedbyaClassAGroundFault
Circuit Interrupter, or RCD.
• Resetcircuitbreaker.Ifcircuitbreakertrips
repeatedly, your electrical system may have a
defect. Turn off circuit breaker and call an
electrician to correct the problem.
• Letthemotorcooldownandrestartagain.
• AdjustthechlorineandpHlevel.Consultyourlocal
swimming pool supply stores.
• Loadwithfiltersand,see“sandloadinginstructions”.
• Setvalveto“FILTER”position.
• Operatethefilterforlongerperiods.
• Cleanthestrainerscreenattheinlet.
• Clearanyobstructionsintheintakehosebydischargingit
inside pool wall.
• Tightenhosenuts,checkhosesfordamage,checkpool
water level.
• Backwashfilter.
• Installthenozzleattheupperpositionofthepoolinlet,and
the strainer at the lower position of the pool outlet.
• Removeabout1”ofsandifnecessary.
• Removeanypoolvacuumingdeviceattachedtothe
system line.
• Turnoffpump,clearanydebrisorobstructionintheoutlet,
remove all air from the filter pump and turn pump on again.
• Turnoffpump,ifwaterleakingfromthevacuumrelease
valve, then release valve needs to be replaced. Contact
Intex Service Center immediately to order replacement.
Youmaycoverreleasevalvewiththecaptemporarilyif
you ensure that the strainer cover / strainer grid is installed
and you Do Not run the pump while pool is occupied.
• Fillpooltocorrectwaterlevel.
• Cleanstrainerscreensatpoolinlet.
• Tightenhosenuts,checkhosefordamage.
• ContactIntexservicecenter.
• Remove6-wayvalvecoverandensurethe
o-ring is in place.
• Cleansandtanko-ringwithgardenhosewater.
• Tightentheclampwithwrenchsupplied.
• ContactIntexservicecenter.
• Tighten/reinstallhosenut.
• Ensureo-ring/L-shapeo-ringisinplaceand
not damaged.
• Turnoffthepumpandrestart5minuteslater.
• Re-setthetimer.
• ContactIntexservicecenter.
• Clearanyobstructionsintheintakeby
unscrewing it from the 6-way valve.
• ContactIntexservicecenter.
• UseonlyNo.20silicasandwithparticlesize
range 0.45 to 0.85 mm (0.018 to 0.033 inches)
and a Uniformity Coefficient less than 1.75.
• Changesand.
FILTER MOTOR
FAILS TO START
FILTERDOESN’T
CLEANPOOL
FILTERDOESN’T
PUMP WATER OR
FLOWISVERY
SLOW
PUMPDOESN’T
WORK
6-WAYVALVE/
COVERLEAKING
HOSELEAKING
TIMER IS
INACCURATEOR
TIMERCAN'TBESET
PRESSUREGAUGE
DOESN’TWORK
SANDISFLOWING
BACKINTOTHE
POOL
• Themotorisnotpluggedin.
• TheGFCI/RCDcircuitbreakeris
tripped.
• Motortoohotandoverload
protection is shut off.
• ImproperchlorineorpHlevels.
• Nofilteringmediaintank.
• Wrong6-wayvalvesettingposition.
• Excessivelydirtypool.
• Thestrainerscreenisrestricting
the water flow.
• Cloggedinletordischarge.
• Anairleakontheintakeline.
• Excessivelydirtypool.
• Sandmediacloggedwithdirt.
• Nozzleandstrainerconnections
are reversed.
• Crustingorcakingonthefiltering
sand surface.
• Poolvacuumingdeviceattached
to the system.
• Thevacuumreleasevalveonthe
plunger valve is activated.
• Thevacuumreleasevalveonthe
plunger valve is leaking.
• Lowwaterlevel.
• Strainerscreencloggedup.
• Anairleakontheintakehose.
• Faultymotorortheimpellerisjammed.
• Sandtanko-ringmissing.
• Sandtanko-ringdirty.
• Flangeclampnottight.
• 6-wayvalvedamage.
• Hosenutnotsecurelytight.
• Hoseconnectionfitting
o-ring/L-shape o-ring missing.
• Possibleinnertimerdefective.
• Cloggedinletofthepressure
gauge.
• Pressuregaugedamage.
• Sandistoosmall.
• Sandbediscalcified.

Related product manuals