TROUBLESHOOTING (continued)
LED PANEL
CODE
PROBLEM SOLUTION
LED Panel Code Flash & Alarm On (
NOTE
: Always turn off the power before cleaning and servicing).
E81
Transmission signal failure.
Reset the GFCI/RCD, restart all over again.
Place the control panel within 5 m (16 ft) of the control base unit.
Press and hold POWER button for 5 seconds to turn off and charge the
panel again.
If problem persists, contact Intex Service Center.
E90
• No water ow.
Turn off and unplug the control unit.
Ensure the outlet cover grid is clean and free from obstructions.
Clean or replace the cartridge, see Maintenance and Storage section.
Ensure the in/outlet connections on the spa tub and lter pump are not blocked.
Keep the spa water properly sanitized to ensure a clean and unclogged lter
cartridge.
Turn off and unplug the control unit. Plug the GFCI/RCD and restart all over
again.
If problem persists, contact Intex Service Center.
E91
Dirt or scale on titanium plates.
Low salt level/No salt.
Electrolytic cell cord is loose.
Possible electrolytic cell failure.
Remove the electrolytic cell for inspection. Clean it if necessary. See
“Maintenance”.
Add salt. See “Salt Level Information”.
Ensure that the cell cord is plugged rmly into the cell receptacle.
Contact Intex Service Center. Replace the cell if needed.
E92
High salt level.
Partially drain the pool and re ll it with fresh water. See “Salt Level Information”.
If problem persists, contact Intex Service Center.
E94
Water temperature too low.
If the ambient temperature is below 39°F (4°C), we recommend not to
use the spa.
Turn off and unplug the control unit. Plug the GFCI/RCD and restart all
over again.
Turn off and unplug the control unit, add some warm water to raise the
spa water temperature above 41°F (5°C), then press the button to
heat up the water to the desired temperature.
If problem persists, contact Intex Service Center.
E95
Water temperature too high.
Turn off and unplug the control unit. When the water has cooled down,
plug the GFCI/RCD and restart all over again.
Turn the heater off, then press the lter and jet buttons to lower the
water temperature.
If problem persists, contact Intex Service Center.
E96
• System Error.
Turn off and unplug the control unit. Plug the GFCI/RCD and restart all over again.
If problem persists, contact Intex Service Center.
E97
• Dry- re Protection.
Contact Intex Service Center.
E99
Water temperature sensor broken.
Contact Intex Service Center.
END
After 72 hours of continuous
heating operation, the pump
will hibernate automatically.
The rapid heating and water
ltration functions are disabled.
Press the button to re-active the lter pump.
NO LED
DISPLAY
LED display is off
Charging Failed
Control Panel failure.
Press any button to reactivate the control panel.
Reset the GFCI/RCD, restart all over again and charge the control panel again.
Make sure the surface between the back of the control panel and the control
base recessed channel is clean, dry and free of obstruction.
If problem persists, contact Intex Service Center.