EasyManua.ls Logo

Intex Quickfill AP619D - TROUBLESHOOTING GUIDE

Intex Quickfill AP619D
6 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(17PO) AP619D/AP619DP-22 ELECTRIC PUMP ENGLISH 4.875” X 7.25” 12/04/2021
English
17PO
READ AND SAVE THESE INSTRUCTIONS
Page 6
©2021 Intex Marketing Ltd. - Intex Development Co. Ltd. - Intex Recreation Corp. All rights reserved/Tous droits réservés/Todos los derechos
reservados/Alle Rechte vorbehalten. Printed in China/Imprimé en Chine/Impreso en China/Gedruckt in China.
®™Trademarksusedinsomecountriesoftheworldunderlicensefrom/®™Marquesutiliséesdanscertainspayssouslicencede/Marcasregistradas
utilizadasenalgunospaísesdelmundobajolicenciade/WarenzeichenverwendetineinigenLändernderWeltinLizenzvon/Intex Marketing Ltd. to/à/
a/an Intex Development Co. Ltd., Hong Kong & Intex Recreation Corp., P.O. Box 1440, Long Beach, CA 90801•DistributedintheEuropeanUnion
by/Distribuédansl’UnionEuropéennepar/DistribuidoenlauniónEuropeapor/VertriebinderEuropäischenUniondurch/Intex Trading B.V., Venneveld
9, 4705 RR Roosendaal – The Netherlands
www.intexcorp.com
PROBLEM
CAUSE SOLUTION
Air leakage
between internal air
pump and the pump
holder frame
•Pumpnotsecurely
attached.
•PumpO-ringis
dirty.
•Internalairbed
beam threads are
caught between
the internal air
pump and the
pump holder frame.
•PumpO-ringis
twisted and/or
damaged.
•Whileholdingthepumpouterrim,pushinand
turn the pump fully clockwise until the two side
tabs lock into place.
•Remove the pump from the airbed, remove
the O-ring from the pump and clean it with
water.CarefullyreplacetheO-ringbacktothe
pump as to prevent dust, lint from sticking onto
the O-ring again. Also make sure the pump
holder frame inner wall is free from dust, hair
or lint.
•Removetheinternalairpumpandcarefully
replace the pump back making sure the internal
airbed beam threads are away from the pump
holder frame.
•Removethepumpfromtheairbed,makesure
the O-ring is not damaged and/or twisted.
Realign the O-ring or replace a new O-ring.
ContactIntexservicecenterforreplacement.
Air pump does not
work
•Notconnectedto
an electrical outlet
socket.
•Pumpmotor
thermo-protector
activated.
•Internalairpump
defective.
•Makesurethepumpispluggedintothe
correct power outlet, then turn the control dial
fully clockwise to the inflation position.
•
Turn off and disconnect the power cord from the
power outlet, let the pump rest for more than
30 minutes before resume the use of the pump.
•Remove the internal air pump from the airbed
andkeeptheairbedinasafeplace.Contact
Intexservicecenterforaninternalairpump
replacement.
Pump motor is
running but airbed
isnotinatingor
deating
•Theinflationor
deflation mode is
not set yet.
•
Turn the control dial fully clockwise until it
stops to inflate the airbed. Or turn the control
dial fully counterclockwise until it stops to
deflate the airbed.
Afterinationairis
escaping through
the pump air
passage or through
themanualination
port
•Thepumpair
passage is not
completely closed.
•Themanual
inflation port cap is
not securely closed.
•Makesuretheairpassageisclosedby
turning the control dial to the center closed /
pump off position.
•Pushthecapfirmlyintothemanualinflation
port.
TROUBLESHOOTING GUIDE