Electromagneticimmunity
Immunitytest
IEC60601testlevelCompliancelevelElectromagneticenvironmentguidance
Electrostaticdischarge
(ESD)
IEC61000-4-2
±8kVcontact
±2kV,±4kV,±8kV,
±15kVair
±8kVcontact
±2kV,±4kV,±8kV,
±15kVair
Floorsshouldbewood,concreteorceramictile.
Ifoorsarecoveredwithsyntheticmaterial,the
relativehumidityshouldbeatleast30%.
Electricalfast
transient/burst
IEC61000-4-4
±2kVforpowersupply
lines
±1kVforInput/output
lines
±2kVforpowersupply
lines
±1kVfor
interconnectingcable
Mainspowerqualityshouldbethatofatypical
commercialorhospitalenvironment.
Surge
IEC61000-4-5
±1kVlinetoline
±2kVlinetoearth
±1kVlinetolineMainspowerqualityshouldbethatofatypical
commercialorhospitalenvironment.
Interruptionsand
voltagevariationson
powersupplyinput
lines
IEC61000-4-11
<5%U
T
(>95%dipin
U
T
)
for0.5cycle
40%U
T
(60%dipinU
T
)
for5cycles
70%U
T
(30%dipinU
T
)
for25cycles
<5%U
T
(>95%dipin
U
T
)
for5sec
<5%U
T
(>95%dipin
U
T
)
for0.5cycle
40%U
T
(60%dipinU
T
)
for5cycles
70%U
T
(30%dipinU
T
)
for25cycles
<5%U
T
(>95%dipin
U
T
)
for5sec
Mainspowerqualityshouldbethatofa
typicalcommercialorhospitalenvironment.
Iftheuserofthedevicerequirescontinued
operationduringpowermainsinterruptions,itis
recommendedthatthedevicebepoweredfrom
anuninterruptiblepowersupplyorabattery.
Powerfrequency
(50/60Hz)magnetic
eld
IEC61000-4-8
30A/m30A/m
Powerfrequencymagneticeldsshouldbeat
levelscharacteristicofatypicallocationina
typicalcommercialorhospitalenvironment.
NOTE:U
T
isthea.c.mainsvoltagepriortoapplicationofthetestlevel.
Immunitytest
IEC60601testlevelCompliancelevelElectromagneticenvironmentguidance
PortableandmobileRFcommunicationsequipment
shouldbeusednoclosertoanypartoftheCT515,
includingcables,thantherecommendedseparation
distancecalculatedfromtheequationapplicabletothe
frequencyofthetransmitter.
Recommendedseparationdistance:
3V
rms
150kHzto80MHz
3V
rms
150kHzto80MHz
ConductedRF
IEC61000-4-6
6V
rms
inISMbands6V
rms
inISMbands
d=[3.5/V
1
]x√P
RadiatedRF
IEC61000-4-3
10V/m
80MHzto2.7GHz
10V/m
80MHzto2.7GHz
d=1.12x√P80MHzto800MHz
d=2.3x√P800MHzto2.5GHz
385MHz-5785MHz
Testspecications
forENCLOSURE
PORTIMMUNITY
toRFwireless
communication
equipment(Refer
totable9ofIEC
60601-1-2:2014)
385MHz-5785MHz
Testspecications
forENCLOSURE
PORTIMMUNITY
toRFwireless
communication
equipment(Refer
totable9ofIEC
60601-1-2:2014)
WherePisthemaximumoutputpowerratingofthe
transmitterinwatts(W)accordingtothetransmitter
manufactureranddistherecommendedseparation
distanceinmeters(m).
FieldstrengthsfromxedRFtransmitters,as
determinedbyanelectromagneticsitesurvey
a)
,should
belessthanthecompliancelevelineachfrequency
range
b)
.
Interferencemayoccurinthevicinityofequipment
markedwiththefollowingsymbol: