Invacare®SoftformActive®2withRXpump
4Setup
4.1Safetyinformation
WARNING!
Electricalshockhazard!
–Donotremovecontrolunitshroud.
–Refertoqualiedservicepersonnel.
–Beforeperforminganymaintenancetothe
controlunit,disconnectthepowerleadfrom
thewalloutlet.
–Donotinsertitemsintoanyopeningsofthe
controlunit.Doingsomaycausereorelectric
shockbyshortingtheinternalcomponents.
–Thecontrolunitmustbekeptawayfromall
heatsourcesandradiatorsduringoperation.
–Connecttheequipmenttoatwoorthreeprong
walloutletusingthevemeterpowerlead
providedwiththeproduct.
–Positionthedeviceinsuchawaythatensures
accesstothepowerswitchandCPRConnector
atalltimes.
WARNING!
Ifthisequipmentismodied,appropriate
inspectionandtestingmustbeconductedto
ensurecontinuedsafeuseoftheequipment.
–Donotmodifythisequipmentwithout
authorizationofthemanufacturer.
WARNING!
Riskofentrapment!
Patiententrapmentwiththebedsiderails
maycauseinjuryordeath.Athoroughpatient
assessmentshouldbecompletedandmonitored
andtheequipmentshouldbeusedasspecied
andmaintainedtoreducetheriskofentrapment.
Variationsinbedsideraildimensions,and
mattressthickness,sizeanddensitycouldincrease
theriskofentrapment.
–Mattressmusttbedframeandsiderailsto
preventpatiententrapment.Followthebed
manufacturer’sinstructions.
–Afteranyadjustments,repairorserviceand
beforeuse,makesureallattachinghardwareis
tightenedsecurely.Siderailswithdimensions
differentfromtheoriginalequipmentsupplied
orspeciedbythebedmanufacturermay
notbeinterchangeableandmayresultin
entrapmentorotherinjury.
WARNING!
Thismattressisrecommendedtobeinstalledon
medicalbedframeswithbedsiderailsorassist
rails.Itispreferredthattherailstobeinthe
raisedpositionwheneverthepatientisonthe
bed.Healthcareprofessionalsassignedtoeach
caseshouldmakethenaldecisionastowhether
sideassistrailsarewarrantedafterassessing
patientriskofentrapment.
Controlsonthefootboardmaybeobstructedby
thecontrolunitonafewbedframes.Itmaybe
necessarytorelocatethecontrolunit.
–Beforeplacingthepatientonthebed,check
thatairhosesandpowercordareclearof
movingbedcomponents.
–Operateallbedframemotorizedfunctions
throughtheirfullrangeofmotiontobecertain
thatthereisnopulling,interferenceorpinching.
–Takecarewhenpositioninghosesandcables
toeliminatetheriskoftrippinghazardsor
strangulation.
4.2Installingthesystem
1.Hangthecontrolunitbymeansofthe2builtinhangers
Aattheendofthebedorplaceitonahorizontal
surface.(Placingthecontrolunitontheoorwillnot
affecttheperformance,butmayexposeittoaccidental
damage.)
2.ConnecttheCPRhoseEtoairoutletsonthemattress
andcontrolunitB,ensuringthatthehoseisnotkinked
ortwisted.Allowspaceforbedrailstodropfreely.
3.Connectthemainspowercabletothepowersupply
socketCofthecontrolunitandasuitableoutlet.
4.Switchonmainspoweroftheoutletifpresent.
5.MovethemechanicalswitchDontheleftsideofthe
ControlunittotheOnposition.Afaintsinglebeep
soundsandthesystemincyclelightasheswhilethe
systempowersup.
Referto8Troubleshooting,page15iftheindicatorisnot
ashing.
81627707-D