  • T
    Tiffany JonesSep 23, 2025
    What to do if Invertek Drives ODE-3-120070-1F12 reports '4-20mA Signal Lost'?
    • C
      Chad BarnettSep 23, 2025
      If the Invertek Drives DC drive indicates '4-20mA Signal Lost', press the stop key. If the fault persists, consult your supplier.
  • B
    Brian GarciaAug 23, 2025
    What to do if Invertek Drives ODE-3-120070-1F12 shows 'Under voltage on DC bus'?
    • J
      Jonathon RhodesAug 23, 2025
      If your Invertek Drives DC drive displays an 'Under voltage on DC bus' error during operation, it means the incoming supply voltage is too low. Check the incoming power supply voltage and all components in the power feed line to the drive.
  • K
    Kevin LarsonAug 25, 2025
    How to fix heatsink over temperature on Invertek Drives ODE-3-120070-1F12 DC Drives?
    • A
      Ann OrtizAug 25, 2025
      If the Invertek Drives DC drive's heatsink is overheating, ensure the ambient temperature around the drive is within the specified limits.
  • T
    tinawilsonAug 26, 2025
    What does Output Fault mean on Invertek Drives DC Drives?
    • J
      Jessica SpencerAug 27, 2025
      If the Invertek Drives DC drive indicates an output fault, which may be due to a missing phase or unbalanced motor phase currents, check the motor and its connections.
  • C
    Cole McgeeAug 27, 2025
    What causes Motor PTC thermistor trip on Invertek Drives ODE-3-120070-1F12?
    • M
      Michelle ThomasAug 27, 2025
      If the Invertek Drives DC drive trips because of motor PTC thermistor over temperature, it means the connected motor thermistor has detected over temperature. Check the wiring connections and the motor itself.
  • P
    powellloriSep 18, 2025
    What to do if Invertek Drives ODE-3-120070-1F12 DC Drives shows Internal memory fault (IO)?
    • K
      Kevin WilsonSep 18, 2025
      If the Invertek Drives DC drive indicates 'Internal memory fault (IO)', press the stop key. If the fault persists, consult your supplier.
  • K
    Kevin RomeroSep 15, 2025
    How to troubleshoot CAN comms loss trip on Invertek Drives ODE-3-120070-1F12 DC Drives?
    • K
      Kim RichardsonSep 15, 2025
      If the Invertek Drives DC drive experiences CAN comms loss, check the incoming CAN connection cable.
  • C
    Carly McintyreSep 16, 2025
    What to do if Invertek Drives ODE-3-120070-1F12 DC Drives shows Output Over Current?
    • T
      Tracy ChristensenSep 16, 2025
      If the Invertek Drives DC drive shows an Output Over Current error, check for short circuits on the motor and connection cable.
  • V
    vincent43Sep 6, 2025
    What to do if Invertek Drives ODE-3-120070-1F12 DC Drives displays 'Motor Thermal Overload (I2t)'?
    • R
      Robert TaylorSep 7, 2025
      If the Invertek Drives DC drive displays 'Motor Thermal Overload (I2t)', check that the supply voltage is within the allowed tolerance for the drive.
  • P
    psantanaSep 3, 2025
    What to do for Autotune Fault on Invertek Drives DC Drives?
    • P
      Paul MartinSep 4, 2025
      If the Invertek Drives DC drive shows an Autotune Fault, where the motor parameters measured during autotune are incorrect, check the motor cable and connections for continuity.

Summary

Quick Start Up

Important Safety Information

Essential safety precautions for installing and operating the Optidrive.

Quick Start Process

A step-by-step guide to quickly set up and begin operating the drive.

Power & Control Wiring

Connection Diagram

A clear diagram illustrating all power and control terminal connections.

Protective Earth (PE) Connection

Critical safety information for proper grounding and earth conductor requirements.

Incoming Power Connection

Instructions for correctly wiring the AC power supply to the drive.

Motor Connection

Guidance on connecting the motor cables to the drive's output terminals.

Control Terminal Connections

Details on connecting digital and analog signals to control terminals.

Operation

Managing the Keypad

Explanation of keypad functions for navigation, parameter access, and drive control.

Changing Parameters

Step-by-step guide to modify drive parameter values using the keypad interface.

Resetting a Fault

How to clear a drive fault condition and resume operation.

Parameters

Standard Parameters

Detailed descriptions and settings for essential drive parameters.

Troubleshooting

Fault Code Messages

A comprehensive list of fault codes, their meanings, and suggested corrective actions.

Invertek Drives ODE-3-120070-1F12 Specifications

General IconGeneral
BrandInvertek Drives
ModelODE-3-120070-1F12
CategoryDC Drives
LanguageEnglish