AC Variable Speed Drive
IP20
0.37kW – 37kW / 0.5HP – 50HP
110 480V Single and 3 Phase Input
1
2
3
4
5
6
7
8
9
10
User Manual
Quick Start Up
General Information
and Ratings
Mechanical Installation
Power & Control Wiring
Operation
Parameters
Analog and Digital Input
Macro Configurations
Modbus RTU
Communications
Technical Data
Troubleshooting
EMC L1 L2 L3

Table of Contents

Questions and Answers

  • J
    Johnny BallSep 23, 2025
    What to do if Invertek Drives ODE-3-120023-1F12 DC Drives reports '4-20mA Signal Lost'?
    • B
      Bruce BradshawSep 23, 2025
      If the Invertek Drives DC drive indicates '4-20mA Signal Lost', press the stop key. If the fault persists, consult your supplier.
  • C
    Christina MaloneAug 23, 2025
    What to do if Invertek Drives DC Drives shows 'Under voltage on DC bus'?
    • C
      Curtis CampbellAug 23, 2025
      If your Invertek Drives DC drive displays an 'Under voltage on DC bus' error during operation, it means the incoming supply voltage is too low. Check the incoming power supply voltage and all components in the power feed line to the drive.
  • M
    mary06Aug 25, 2025
    How to fix heatsink over temperature on Invertek Drives ODE-3-120023-1F12?
    • K
      Kim AdamsAug 25, 2025
      If the Invertek Drives DC drive's heatsink is overheating, ensure the ambient temperature around the drive is within the specified limits.
  • R
    Roger MelendezAug 27, 2025
    What does Output Fault mean on Invertek Drives ODE-3-120023-1F12 DC Drives?
    • M
      Miranda MontesAug 27, 2025
      If the Invertek Drives DC drive indicates an output fault, which may be due to a missing phase or unbalanced motor phase currents, check the motor and its connections.
  • T
    Tammy WilliamsAug 27, 2025
    What causes Motor PTC thermistor trip on Invertek Drives ODE-3-120023-1F12 DC Drives?
    • C
      Christina NelsonAug 27, 2025
      If the Invertek Drives DC drive trips because of motor PTC thermistor over temperature, it means the connected motor thermistor has detected over temperature. Check the wiring connections and the motor itself.
  • T
    Teresa FrazierSep 18, 2025
    What to do if Invertek Drives ODE-3-120023-1F12 shows Internal memory fault (IO)?
    • S
      samanthawilliamsSep 18, 2025
      If the Invertek Drives DC drive indicates 'Internal memory fault (IO)', press the stop key. If the fault persists, consult your supplier.
  • G
    gracebarnettSep 15, 2025
    How to troubleshoot CAN comms loss trip on Invertek Drives ODE-3-120023-1F12 DC Drives?
    • S
      Steven JensenSep 15, 2025
      If the Invertek Drives DC drive experiences CAN comms loss, check the incoming CAN connection cable.
  • M
    Michael SchwartzSep 16, 2025
    What to do if Invertek Drives ODE-3-120023-1F12 shows Output Over Current?
    • M
      michellegregorySep 16, 2025
      If the Invertek Drives DC drive shows an Output Over Current error, check for short circuits on the motor and connection cable.
  • S
    Sarah OwenSep 6, 2025
    What to do if Invertek Drives ODE-3-120023-1F12 DC Drives displays 'Motor Thermal Overload (I2t)'?
    • T
      Todd AtkinsonSep 7, 2025
      If the Invertek Drives DC drive displays 'Motor Thermal Overload (I2t)', check that the supply voltage is within the allowed tolerance for the drive.
  • E
    Erica BakerSep 4, 2025
    What to do for Autotune Fault on Invertek Drives ODE-3-120023-1F12 DC Drives?
    • B
      Billy MitchellSep 4, 2025
      If the Invertek Drives DC drive shows an Autotune Fault, where the motor parameters measured during autotune are incorrect, check the motor cable and connections for continuity.

Summary

Quick Start Up Guide

Important Safety Information

Crucial safety instructions for installation, operation, and maintenance of the Optidrive. Read before use.

Quick Start Process

Step-by-step guide for initial setup and installation of the Optidrive.

Mechanical Installation

Power and Control Wiring

Protective Earth (PE) Connection

Detailed guidelines for making safe and compliant protective earth connections for the drive.

Operation

Managing the Keypad

Explains the function of each keypad button for navigating and controlling the drive.

Changing Parameters

Step-by-step guide on how to access and modify drive parameters using the keypad.

Resetting Parameters

Instructions for resetting all drive parameters to their factory default settings.

Parameters

Standard Parameters

Details of standard parameters, their ranges, defaults, and units for drive configuration.

Extended Parameters

Comprehensive list and explanation of extended parameters for advanced drive configuration.

Advanced Parameters

Details of advanced parameters for fine-tuning motor control and drive performance.

Troubleshooting

Fault Code Messages

Lists fault codes, their descriptions, and suggested remedies for diagnosing issues.

Invertek Drives ODE-3-120023-1F12 Specifications

General IconGeneral
Output Current23A
Horsepower3 HP
Power Rating2.2 kW
EnclosureIP20
CommunicationModbus RTU
Humidity95% non-condensing
Control MethodV/Hz
Operating Temperature-10°C to 50°C
Cooling MethodFan