If the Invertek Drives DC drive indicates '4-20mA Signal Lost', press the stop key. If the fault persists, consult your supplier.

What to do if Invertek Drives ODE-3-120043-1F12 reports '4-20mA Signal Lost'?
If the Invertek Drives DC drive indicates '4-20mA Signal Lost', press the stop key. If the fault persists, consult your supplier.
What to do if Invertek Drives ODE-3-120043-1F12 DC Drives shows 'Under voltage on DC bus'?
If your Invertek Drives DC drive displays an 'Under voltage on DC bus' error during operation, it means the incoming supply voltage is too low. Check the incoming power supply voltage and all components in the power feed line to the drive.
How to fix heatsink over temperature on Invertek Drives ODE-3-120043-1F12?
If the Invertek Drives DC drive's heatsink is overheating, ensure the ambient temperature around the drive is within the specified limits.
What does Output Fault mean on Invertek Drives ODE-3-120043-1F12?
If the Invertek Drives DC drive indicates an output fault, which may be due to a missing phase or unbalanced motor phase currents, check the motor and its connections.
What causes Motor PTC thermistor trip on Invertek Drives ODE-3-120043-1F12?
If the Invertek Drives DC drive trips because of motor PTC thermistor over temperature, it means the connected motor thermistor has detected over temperature. Check the wiring connections and the motor itself.
What to do if Invertek Drives ODE-3-120043-1F12 DC Drives shows Internal memory fault (IO)?
If the Invertek Drives DC drive indicates 'Internal memory fault (IO)', press the stop key. If the fault persists, consult your supplier.
How to troubleshoot CAN comms loss trip on Invertek Drives ODE-3-120043-1F12 DC Drives?
If the Invertek Drives DC drive experiences CAN comms loss, check the incoming CAN connection cable.
What to do if Invertek Drives DC Drives shows Output Over Current?
If the Invertek Drives DC drive shows an Output Over Current error, check for short circuits on the motor and connection cable.
What to do if Invertek Drives DC Drives displays 'Motor Thermal Overload (I2t)'?
If the Invertek Drives DC drive displays 'Motor Thermal Overload (I2t)', check that the supply voltage is within the allowed tolerance for the drive.
What to do for Autotune Fault on Invertek Drives DC Drives?
If the Invertek Drives DC drive shows an Autotune Fault, where the motor parameters measured during autotune are incorrect, check the motor cable and connections for continuity.
| Brand | Invertek Drives |
|---|---|
| Model | ODE-3-120043-1F12 |
| Category | DC Drives |
| Language | English |
Essential safety guidelines and warnings for installation and operation of the Optidrive E3.
Step-by-step guide for initial setup and configuration of the Optidrive E3.
Schematic showing power and control terminal connections for the Optidrive.
Guidelines and requirements for proper grounding and safety earth conductor connections.
Details on selecting cables, fuses/breakers, and optional input chokes for power supply.
Guidance on connecting motors, including cable types, shielding, and length limitations.
Detailed description of default functions for control terminals 1-11.
Internal overload protection features and motor thermistor connection details.
Explanation of keypad buttons and their functions for navigation and control.
Procedure for navigating and modifying drive parameters using the keypad.
Procedures for resetting parameters to defaults and clearing drive faults.
Detailed descriptions of essential drive parameters for basic configuration and operation.
In-depth parameters for advanced control features, input/output functions, and system setup.
List of fault codes, their descriptions, and suggested remedies for resolving issues.