AC Variable Speed Drive
IP20
0.37kW – 37kW / 0.5HP – 50HP
110 480V Single and 3 Phase Input
1
2
3
4
5
6
7
8
9
10
User Manual
Quick Start Up
General Information
and Ratings
Mechanical Installation
Power & Control Wiring
Operation
Parameters
Analog and Digital Input
Macro Configurations
Modbus RTU
Communications
Technical Data
Troubleshooting
EMC L1 L2 L3

Table of Contents

Questions and Answers

  • L
    Lee BakerSep 23, 2025
    What to do if Invertek Drives DC Drives reports '4-20mA Signal Lost'?
    • J
      Joseph PachecoSep 23, 2025
      If the Invertek Drives DC drive indicates '4-20mA Signal Lost', press the stop key. If the fault persists, consult your supplier.
  • J
    janetspencerAug 23, 2025
    What to do if Invertek Drives ODE-3-340240-3F42 shows 'Under voltage on DC bus'?
    • K
      Kevin GuerraAug 23, 2025
      If your Invertek Drives DC drive displays an 'Under voltage on DC bus' error during operation, it means the incoming supply voltage is too low. Check the incoming power supply voltage and all components in the power feed line to the drive.
  • A
    Amanda SmithAug 25, 2025
    How to fix heatsink over temperature on Invertek Drives DC Drives?
    • E
      Emma PetersAug 25, 2025
      If the Invertek Drives DC drive's heatsink is overheating, ensure the ambient temperature around the drive is within the specified limits.
  • T
    Troy BurchAug 26, 2025
    What does Output Fault mean on Invertek Drives ODE-3-340240-3F42 DC Drives?
    • E
      Elizabeth KingAug 26, 2025
      If the Invertek Drives DC drive indicates an output fault, which may be due to a missing phase or unbalanced motor phase currents, check the motor and its connections.
  • D
    Danielle HarrisonAug 27, 2025
    What causes Motor PTC thermistor trip on Invertek Drives DC Drives?
    • X
      xmoranAug 27, 2025
      If the Invertek Drives DC drive trips because of motor PTC thermistor over temperature, it means the connected motor thermistor has detected over temperature. Check the wiring connections and the motor itself.
  • C
    cohenedwardSep 18, 2025
    What to do if Invertek Drives ODE-3-340240-3F42 shows Internal memory fault (IO)?
    • C
      Carrie SalinasSep 18, 2025
      If the Invertek Drives DC drive indicates 'Internal memory fault (IO)', press the stop key. If the fault persists, consult your supplier.
  • S
    shelleywolfSep 15, 2025
    How to troubleshoot CAN comms loss trip on Invertek Drives DC Drives?
    • K
      Kayla RiversSep 15, 2025
      If the Invertek Drives DC drive experiences CAN comms loss, check the incoming CAN connection cable.
  • G
    Gina FosterSep 16, 2025
    What to do if Invertek Drives ODE-3-340240-3F42 DC Drives shows Output Over Current?
    • D
      daniel02Sep 17, 2025
      If the Invertek Drives DC drive shows an Output Over Current error, check for short circuits on the motor and connection cable.
  • K
    Kimberly HayesSep 6, 2025
    What to do if Invertek Drives ODE-3-340240-3F42 displays 'Motor Thermal Overload (I2t)'?
    • J
      Jimmy ThompsonSep 7, 2025
      If the Invertek Drives DC drive displays 'Motor Thermal Overload (I2t)', check that the supply voltage is within the allowed tolerance for the drive.
  • J
    James BuchananSep 4, 2025
    What to do for Autotune Fault on Invertek Drives DC Drives?
    • D
      david28Sep 4, 2025
      If the Invertek Drives DC drive shows an Autotune Fault, where the motor parameters measured during autotune are incorrect, check the motor cable and connections for continuity.

Summary

Quick Start Up

Important Safety Information

Crucial safety warnings and precautions for installing and operating the Optidrive.

Quick Start Process

Step-by-step guide for initial setup and basic operation of the drive.

Mechanical Installation

Power and Control Wiring

Power and Control Connection Diagram

Schematic illustrating power and control terminal connections for the drive.

Protective Earth (PE) Connection Guidelines

Essential guidelines for proper grounding and safety earth connections.

Incoming Power Connection Details

Details on cable selection, fuse/breaker, and optional input chokes.

Motor Connection Guidelines

Guidelines for connecting the motor, including cable types and lengths.

Operation

Keypad Operation and Navigation

Explanation of keypad buttons and their functions for controlling the drive.

Parameter Adjustment via Keypad

Procedure for navigating and modifying drive parameters via the keypad.

Fault Reset Procedure

Procedure for clearing fault conditions and restarting the drive.

Parameters

Standard Parameters

Detailed descriptions of frequently used standard drive parameters.

Extended Parameters

Descriptions of advanced parameters for more detailed drive configuration.

Advanced Parameters

Further advanced parameters for fine-tuning motor control and drive functions.

Analog and Digital Input Macro Configurations

Modbus RTU Communications

Modbus Register Map Details

Table listing Modbus registers for reading and writing drive parameters.

Troubleshooting

Troubleshooting Fault Codes and Remedies

List of fault codes, descriptions, and suggested remedies for diagnosing issues.