What to do if Invertek Drives ODE-3-220105-1F42 reports '4-20mA Signal Lost'?
- CCameron TorresSep 23, 2025
If the Invertek Drives DC drive indicates '4-20mA Signal Lost', press the stop key. If the fault persists, consult your supplier.

What to do if Invertek Drives ODE-3-220105-1F42 reports '4-20mA Signal Lost'?
If the Invertek Drives DC drive indicates '4-20mA Signal Lost', press the stop key. If the fault persists, consult your supplier.
What to do if Invertek Drives ODE-3-220105-1F42 DC Drives shows 'Under voltage on DC bus'?
If your Invertek Drives DC drive displays an 'Under voltage on DC bus' error during operation, it means the incoming supply voltage is too low. Check the incoming power supply voltage and all components in the power feed line to the drive.
How to fix heatsink over temperature on Invertek Drives ODE-3-220105-1F42 DC Drives?
If the Invertek Drives DC drive's heatsink is overheating, ensure the ambient temperature around the drive is within the specified limits.
What does Output Fault mean on Invertek Drives DC Drives?
If the Invertek Drives DC drive indicates an output fault, which may be due to a missing phase or unbalanced motor phase currents, check the motor and its connections.
What causes Motor PTC thermistor trip on Invertek Drives ODE-3-220105-1F42?
If the Invertek Drives DC drive trips because of motor PTC thermistor over temperature, it means the connected motor thermistor has detected over temperature. Check the wiring connections and the motor itself.
What to do if Invertek Drives DC Drives shows Internal memory fault (IO)?
If the Invertek Drives DC drive indicates 'Internal memory fault (IO)', press the stop key. If the fault persists, consult your supplier.
How to troubleshoot CAN comms loss trip on Invertek Drives DC Drives?
If the Invertek Drives DC drive experiences CAN comms loss, check the incoming CAN connection cable.
What to do if Invertek Drives ODE-3-220105-1F42 shows Output Over Current?
If the Invertek Drives DC drive shows an Output Over Current error, check for short circuits on the motor and connection cable.
What to do if Invertek Drives DC Drives displays 'Motor Thermal Overload (I2t)'?
If the Invertek Drives DC drive displays 'Motor Thermal Overload (I2t)', check that the supply voltage is within the allowed tolerance for the drive.
What to do for Autotune Fault on Invertek Drives ODE-3-220105-1F42 DC Drives?
If the Invertek Drives DC drive shows an Autotune Fault, where the motor parameters measured during autotune are incorrect, check the motor cable and connections for continuity.
| Output Current | 105A |
|---|---|
| Phase | Single Phase |
| Communication Interface | Modbus RTU |
| Enclosure Rating | IP20 |
| Control Method | V/F Control, Sensorless Vector Control |
| Protection Features | Overload, Overvoltage, Undervoltage |
| Input Voltage | 220VAC |
Crucial safety warnings for installation and operation of the variable speed drive.
Recommendations for mounting drives within enclosures for optimal cooling and protection.
Illustrates the overall wiring connections for power and control terminals of the drive.
Details the importance and methods for establishing proper protective earth connections.
Covers cable selection, fixed installation, and protective devices for incoming power.
Guidelines for connecting the motor to the drive, including cable types and limitations.
Lists default functions for control terminals, including digital and analog I/O.
Step-by-step guide on how to navigate and modify drive parameters using the keypad.
Details standard parameters for motor setup, speed limits, and ramp times.
Covers extended parameters for digital inputs, relay outputs, and preset frequencies.
Details macro functions for terminal control mode, mapping digital inputs to functions.
Details macro functions for keypad control mode, mapping inputs to functions.
Details macro functions for fieldbus control modes, mapping inputs to functions.
Lists common fault codes, their descriptions, and suggested remedies for troubleshooting.