Goodrive100-PV Series Solar Pumping VFD                         Installation guidelines 
11 
3PH (1PH) AC input terminals, connected to the grid 
Note: Use the screws equipped with the VFD for wiring. 
Solar cell panel input terminals 
3PH/1PH AC output terminals, connected to  the pump 
motor 
Note: 1PH motors must connect to terminals U and W. 
Safety  protection  grounding  terminal.  Each  VFD  must 
be grounded 
Description for -SS2 single-phase output models 
1) Generally,  the output terminals U  and W of  the  VFD  connect  to  the phase cables of the 
single-phase motor. 
2) If the single-phase pump cannot be started, the two-phase control method must be used, 
and  the  start-up  and  running capacitors  (if any)  of  the  motor  must  be  removed.  The  figure 
below shows the internal wiring of the common single-phase motor. In the figure, L1, L2, C1, 
and  C2  indicate  the  running  winding,  start-up  winding,  running  capacitor,  and  start-up 
capacitor. When the motor speed exceeds 75% of the rated speed, the start-up  capacitor is 
switched off. 
 
Internal  wiring  of  the  single-phase  motor  winding  after  removing  the  starting  and  running 
capacitor: