Goodrive100-PV Series Solar Pumping VFD Function parameters 
38 
Detailed illustration of parameters 
QUICK/JOG the 
shifting sequence 
of running 
command 
When  P07.02=6,  set  the  shifting 
sequence of running command channels. 
0:  Keypad  control→terminal  control 
→communication control 
1: Keypad control←→terminals control 
2:  Keypad  control←→communication 
control 
3:  Terminals  control←→communication 
control 
Select  the  stop  function  by  STOP/RST. 
STOP/RST is effective in any state for the 
keypad reset.   
0: Only valid for the keypad control   
1:  Both  valid  for  keypad  and  terminals 
control   
2:  Both  valid  for  keypad  and 
communication control 
3: Valid for all control modes 
When  the  VFD  is  configured  with  the 
boost module, this function code displays 
the  temperature  of  this  module.  This 
function code is valid only in the AC mode. 
This  function  code  is  invalid  in  the  PV 
mode. 
-20.0–120.0° 
Inverter module 
temperature 
Display the power used by the VFD.