User’s
password
0~65535
The password protection will be valid when setting any
non-zero number.
00000: Clear the previous user’s password, and make the
password protection invalid.
After the user’s password becomes valid, if the password is
incorrect, users cannot enter the parameter menu. Only
correct password can make the user check or modify the
parameters. Please remember all users’ passwords.
Retreat editing state of the function codes and the password
protection will become valid in 1 minute. If the password is
available, press PRG/ESC to enter into the editing state of
the function codes, and then “0.0.0.0.0” will be displayed.
Unless input right password, the operator can not enter into
it.
Note: Restoring to the default value can clear the
password, please use it with caution.
0 ○
Parameter
copy
0:No operation
1:Upload the local function parameter to the keypad
2:Download the keypad function parameter to local
address(including the motor parameters)
3:Download the keypad function parameter to local address
(excluding the motor parameter of P02 and P12 group)
4:Download the keypad function parameters to local
address (only for the motor parameter of P02 and P12
group)
Note: After finish 1~4, the parameter will restore to 0 and
the uploading and downloading does not include P29.
0 ◎
Key
function
selection
0x00~0x27
Ones:QUICK/JOG key function
0:Null
1:Jogging
2:Switch display state via shift key
3:Switch between FWD/REV rotation
4:Clear UP/DOWN setting
5:Coast to stop
0x01 ◎