Goodrive300 Series VFD Function parameters
112
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
synchronous
motor 2
value of P12.20P12.22 will
renew automatically. These
parameters are basic
parameters controlled by
vectors which directly impact
the features.
When P00.15=1, the set value
of P12.23 can be updated
through autotuning
automatically, and there is no
need to change the value of
P12.23; when P00.15=2, the
set value of P12.23 cannot be
updated through autotuning,
please account and update
the value of P12.23.
Note: Users cannot modify
the parameters freely.
model
P12.22
Quadrature
axis
inductance of
synchronous
motor 2
0.01655.35mH
Depend
on
model
P12.23
Back EMF
constant of
synchronous
motor 2
When P00.15=2,
the set value of
P12.23 cannot
be updated by
autotuning,
please count
according to the
following
method.
The
counter-electrom
otive force
constant can be
counted
according to the
parameters on
the name plate of
the motor. There
are three ways to
count:
1. If the name
plate designate
the
counter-electrom
otive force
constant Ke,
then:
E=(Ke×n
N
×2
π)/ 60
2. If the name
plate designate
300