INVT GD300-5R5G-4 Specifications

General IconGeneral
ModelGD300-5R5G-4
CategoryDC Drives
Power5.5kW
Cooling MethodForced air cooling
Enclosure RatingIP20
Rated Power5.5 kW
Control MethodV/F control
Communication InterfaceModbus-RTU
Protection FeaturesOvercurrent, overvoltage, undervoltage, overload, short circuit, overheating
Operating Temperature-10°C to +40°C
Storage Temperature-20°C to +60°C
Relative Humidity≤95% RH (non-condensing)
Altitude≤1000m above sea level
Overload Capacity150% for 60 seconds

Summary

Chapter 1 Safety Precautions

Safety Guide

Provides essential safety guidelines for operating, installing, and maintaining the VFD.

Chapter 2 Quick Start-up

Basic Commissioning

Steps to perform initial setup and basic configuration for VFD operation.

Chapter 4 Installation Guide

Mechanical Installation

Covers physical mounting, environmental conditions, and installation directions.

Standard Wiring

Provides detailed diagrams and instructions for main and control circuit wiring.

Chapter 5 Keypad Operation Procedure

Keypad Operation

Details how to navigate menus, modify function codes, and set parameters via the keypad.

Chapter 6 Function Parameters

General Function Parameters

Comprehensive list and explanation of all VFD function codes and parameters.

P00.00 Speed Control Mode

Selects the motor control mode: Sensorless Vector or SVPWM.

Chapter 7 Basic Operation Instruction

First Powering On

Step-by-step guide for initial power-up and VFD initialization.

Vector Control

Explains the principles and application of vector control for precise motor performance.

Torque Control

Describes torque control mode, focusing on stable torque output and frequency limits.

Parameters of the Motor

Guides on setting motor parameters for optimal VFD performance and autotuning.

Start-up and Stop Control

Details the three starting methods and their logic for VFD operation.

Frequency Setting

Explains various methods for setting the VFD's output frequency.

Digital Input

Explains the programmable functions of digital input terminals.

PID Control

Explains PID control principles and parameter setting for process control.

Fault Procedure

Provides information on identifying, diagnosing, and resolving VFD faults.

Chapter 8 Fault Tracking

Fault Instruction and Solution

Guides users on how to troubleshoot VFD faults after they occur.

VFD Faults and Troubleshooting Resolutions

Detailed table of common VFD faults, their causes, and suggested solutions.

Common Fault Analysis

Flowcharts and descriptions for diagnosing common VFD and motor issues.

Chapter 10 Communication Protocol

RTU Command Code and Communication Data Illustration

Illustrates Modbus RTU command codes, data formats, and examples.

Appendix A Extension Card

PROFIBUS Extension Card

Details the PROFIBUS extension card, its features, and naming rules.

EC-TX-103 Communication Card

Describes the EC-TX-103 communication card, its appearance, and connection.

PROFIBUS-DP Communication

Explains PROFIBUS-DP protocol, data structures, and control/state words.

Appendix B Technical Data

Derating

Explains factors like temperature, altitude, and frequency affecting VFD performance.

Related product manuals