EasyManua.ls Logo

INVT GD300L-011G-4 User Manual

INVT GD300L-011G-4
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Goodrive300-LIFT Series Inver ter

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the INVT GD300L-011G-4 and is the answer not in the manual?

INVT GD300L-011G-4 Specifications

General IconGeneral
ModelGD300L-011G-4
TypeInverter
Output Power11kW
Efficiency≥ 98%
Cooling MethodForced Air Cooling
Protection LevelIP20
Operating Temperature-10°C to +50°C
Input Voltage380V
Communication InterfaceRS485
Storage Temperature-20°C to +60°C
Humidity5~95%, without condensation
AltitudeBelow 1000m, derating above 1000m

Summary

1 Safety precautions

1.4 Safety guide

Provides essential guidelines for safe operation, installation, and maintenance procedures.

2 Precautions for quick application

2.6 Basic commissioning

Guides through essential steps for initial setup and parameter configuration for basic operation.

3 Product overview

3.3 Product specifications

Lists key electrical and technical features, including input/output ratings and control features.

3.6 Rated specifications

Provides detailed rated power, current, voltage, and performance specifications.

4 Installation guide

4.2 Mechanical installation

Covers environmental requirements, installation sites, direction, and mounting methods.

4.3 Wiring

Details main circuit and control circuit wiring, including terminal functions and diagrams.

5 Keypad operation procedure

5.4 Keypad operation

Guides on navigating menus and modifying function codes using the keypad.

6 Function parameters

6.2 Function parameters

Lists and describes the inverter's configurable function parameters for various operations.

7 Commissioning guidelines

7.2 Wiring between the lift controller and inverter

Provides wiring diagrams for multi-step and analog speed running modes.

7.3 Setting basic parameters

Details essential parameters to set after correct wiring for proper inverter operation.

7.4 Debugging running

Guides on testing and adjusting motor parameters, S-curves, and comfortability.

7.5 Lift running mode

Explains different running modes like multi-step, analog tracking, and emergency running.

8 Fault tracking

8.5 Inverter faults and solutions

Lists common inverter faults, their possible causes, and suggested corrective actions.

8.6 Common fault analysis

Provides flowcharts for diagnosing common motor and inverter operational issues.

9 Maintenance and hardware diagnosis

10 Communication protocol

10.3 Application of the inverter

Details the RS485 interface, baud rates, transmission distance, and connection methods.

10.4 RTU command code and communication data illustration

Explains Modbus RTU frame structure, command codes, data addressing, and error checking.

Appendix A Expansion cards

A.5 STO instructions

Explains the Safe Torque Off (STO) function, its logic, faults, and installation checklist.

Appendix B Technical data

Appendix D Peripheral optional parts

D.8 Braking system

Guides on selecting and installing brake resistors or units for sharp braking and high inertia loads.