Goodrive20-EU series VFD Function parameters
98
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
1: Enabled
LED hundreds: User-defined communication
command address
0: Disabled
1: Enabled
P14.07
User-defined
address for
running
commands
0x00000xffff
0x1000
P14.08
User-defined
address for
frequency
setting
0x00000xffff
0x2000
P17 Group Monitoring function
P17.00
Setting
frequency
Display current set frequency of the VFD
Range: 0.00Hz P00.03
P17.01
Output
frequency
Display current output frequency of the VFD
Range: 0.00Hz P00.03
P17.02
Ramp
reference
frequency
Display current ramp reference frequency of the
VFD
Range: 0.00Hz P00.03
P17.03
Output voltage
Display current output voltage of the VFD
Range: 0 1200V
P17.04
Output current
Display current output current of the VFD
Range: 0.0 5000.0A
P17.05
Motor speed
Display the rotation speed of the motor.
Range: 0 65535RPM
P17.06
Torque current
Display current torque current of the VFD
Range: 0.0 5000.0A
P17.07
Magnetized
current
Display current magnetized current of the VFD
Range: 0.0 5000.0A
P17.08
Motor power
Display current power of the motor.
Setting range: -300.0% 300.0%
(the rated current of the motor)
P17.09
Output torque
Display the current output torque of the VFD.
Range: -250.0 250.0%