Goodrive300 Series VFD Function parameters
115
Detailed instruction of parameters
0: No test
1: High-frequency superposition (reserved)
2: Pulse superposition
Source current is the positioning current of the
magnetic pole position. Source current 1 is valid
under the frequency point of current shifting.
Increasing the value can raise the starting torque.
Setting range: 0.0%–100.0% (rated current of the
motor)
Source current is directional current of the
magnetic pole position. Source current 2 is valid
under the frequency point of current shifting.
There is no need to modify the value generally.
Setting range: 0.0%–100.0% (rated current of the
motor)
Shift
frequency of
source current
Valid frequency shifting point between source
current 1 and current 2.
Setting range: 0.00Hz–P00.03 (Max. frequency)
Superposing
frequency
(reserved)
Pulse
superposing
voltage
0.0–300.0% (rated voltage of the motor)
Maladjustment
detection time
Adjust the response of anti-maladjustment.
Bigger load inertia may increase the value, but
the response will be slower.
Setting range: 0.0–10.0s
When the motor speed is faster than the rated
speed, the parameter is valid, if vibration occurs