Goodrive300 Series VFD Function parameters
124
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
reference
control mode.
Range: -3000.03000.0A
P17.35
AC current
Display the value of inlet current in AC side.
Range: 0.05000.0A
0.0A
P17.36
Output torque
Display the output torque. Positive value is in the
electromotion state, and negative is in the power
generating state.
Range : -3000.0Nm3000.0Nm
0.0Nm
P17.37
Count value of
motor
overload
0100 (100 reports OL1 fault)
0
P17.38
PID output
-100.00100.00%
0.00%
P17.39
Wrong
download of
parameters
0.0099.99
0.00