EasyManuals Logo

INVT iMars BG10KTR User Manual

INVT iMars BG10KTR
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
iMars grid-tied solar inverters Safety precautions
8
Keep the installation site away from children and other public places which is
easy to access.
Remove the metal jewelry such as ring and bracelet before installation and
electrical connection to avoid electric shock.
The solar panel exposed to the sunlight may generate dangerous voltage. Users
must cover the solar panel with fully-lightproof materials before electrical
connection
The inverter input voltage should not exceed the maximum input voltage;
otherwise inverter damage may occur.
The positive and negative pole of solar modules can not be grounded, otherwise
irrecoverable damage may occur.
Ensure the proper grounding of the inverter, otherwise, improper connection or
no grounding may cause stop of the inverter.
Ensure reliable installation and electrical connection.
Note: iMars series grid-tied solar inverters are only for crystalline silicon solar modules.
1.2.2 Grid-tied operation
Only qualified electricians are allowed to operate the inverter under the
permission of local power departments.
All electrical connections must meet the electrical standards of the
countries/regions in which the project is located.
Ensure reliable installation and electrical connection before operation.
Do not open the cover of inverter during operation or voltage is present.
1.2.3 Maintenance and inspection
Only qualified electricians are allowed to perform the maintenance, inspection,
and components replacement of the inverter.
Contact with the local dealer or supplier for maintenance.
In order to avoid irrelevant personnel from entering the maintenance area during
maintenance, temporary warning labels must be placed to warn
non-professionals to enter or use fence for isolation.
Before carrying out any maintenance operations, users must disconnect the
breaker on grid side, then disconnect the breaker on PV side and wait for at least

Other manuals for INVT iMars BG10KTR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT iMars BG10KTR and is the answer not in the manual?

INVT iMars BG10KTR Specifications

General IconGeneral
BrandINVT
ModeliMars BG10KTR
CategoryInverter
LanguageEnglish

Related product manuals