EasyManua.ls Logo

Inxpect LBK System - Page 55

Inxpect LBK System
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.2.2 Download the system log
1. Start the Inxpect Safety application.
2. Click Settings and then Activity History.
3. Click DOWNLOAD LOG.
8.2.3 Radar signal errors (SIGNALERROR)
Error Meaning
HEAD FAULT Radar not functioning
HEAD POWER OFF Radar off
MASKING Presence of object obstructing the field of vision of the radar
SIGNAL DYNAMIC Wrong signal dynamic
SIGNAL MIN Signal with dynamic below minimum
SIGNAL MIN MAX Signal with out of range dynamic
SIGNAL MAX Signal with dynamic over maximum
SIGNAL AVG Flat signal
8.2.4 CAN errors (CANERROR)
Error Meaning
TIMEOUT Timeout on message to sensor/controller
CROSS CHECK Two redundant messages do not coincide
SEQUENCE
NUMBER
Message with sequence number different from the expected number
CRC CHECK Packet control code does not match
COMMUNICATION
LOST
Impossible to communicate with the sensor
8.2.5 Temperature errors (TEMPERATUREERROR)
Error Meaning
TEMPERATURE TOOLOW Temperature below minimum
TEMPERATURETOOHIGH Temperature above maximum
8.2.6 Relay errors (RELAY ERROR)
Error Meaning
RELAY1 BAD
MOSFET STATUS
Error on diagnostics signal of MOS relay 1
RELAY2 BAD
MOSFET STATUS
Error on diagnostics signal of MOS relay 2
RELAY1
INCONSISTENT
FEEDBACK
Error on feedback signal of relay 1
RELAY2
INCONSISTENT
FEEDBACK
Error on feedback signal of relay 2
RELAYS SHORT
CIRCUIT
Short-circuit error between two relays or between two relay commands
8.2.7 Sensor/controller voltage errors (POWERERROR)
Error Meaning
UNDERVOLTAGE Undervoltage error for the indicated voltage*
OVERVOLTAGE Overvoltage error for the indicated voltage*
8. Maintenance and troubleshooting
LBK System| Instruction manual v1.3 SEP 2019 |LBK-System_instructions_en v1.3|© 2018-2019 Inxpect SpA