25
Troubleshooting
I had connected the Sensor Cam to an outlet and plugged in the Wire-
less Receiver to the Computer’s USB port. The LED indicator of the
Sensor Cam first shows a blinking Orange then changes to a solid Red,
but I am still not able to use the Interactive Pen.
The Sensor Cam is trying to detect and connect with the Wireless Receiver
when the LED indicator is blinking Orange. If the Sensor Cam has suc-
cessfully detected and is connected with the Wireless Receiver, the LED
indicator will show a solid Green, and it is now ready for use. However, if
no successful connection is made within 20 seconds, the Sensor Cam will
enter into the Sleep Mode and the LED indicator will turn Red. Check that
the Wireless Receiver has been properly plugged into the computer and
is placed within 16 ft (5m) of the Sensor Cam. Turn on the Sensor Cam by
pressing the Sensor Power Button located on the Pen. Make sure the Pen
is pointing at the Sensor Cam while doing so. The Sensor Cam will start to
detect and try to connect with the Wireless Receiver again. Check the LED
indicator, it should show a solid Green indicating a successful connection,
and is now ready for use.
When I tap on the corners during calibration, the dots don’t fall within
the projection screen.
Move the Sensor Cam closer to the area where the corresponding dots do
not appear. Or, move the Sensor Cam further away from the screen. Run the
calibration process again. See Pages 13~15.
The cursor on my screen is jumping around abnormally and I am not
able to control it.
Remove any strong light source or infrared equipment close to the Sensor
Cam, as these may interfere with the Sensor Cam.
During calibration, multiples spots appear or spots appear erratically.
1. Remove any strong light source or infrared equipment close to the Sensor
Cam, as these may interfere with the Sensor Cam.
2. Ensure the projection screen you are using is not made of highly reflective
glass or metal. Such reflective materials affect Sensor Cam’s operation.
The pen trace continually breaks when I write or draw with the
Interactive Pen.
1. The Sensor Cam might be placed too far away from the screen. Move the
Sensor Cam closer to the screen and run the calibration process again. See
Pages 13~15.
2. Pen trace can only occur if the Sensor Cam’s vision field is not blocked.
Please do not draw or write with your body blocking the Sensor Cam.
3. Replace the batteries in the Interactive Pen. Low batteries can have an
adverse effect on pen trace and accuracy.