The dryer is so designed that when an operator opens the dryer door,
the basket and exhaust fan stops. You can expect fast drying from a
laundry dryer. Hot, dry air is properly and effectively moved through
the basket and exhausted through a lint trap to the atmosphere. The
dryer comes equipped with an inclined, self-cleaning lint screen. In
this system, lint accumulates on the underside of the screen until a
blanket approximately 1/4” (6 mm) thick is formed. This blanket of
lint will fall from the screen to the bottom of the dryer cabinet and
should be removed daily, or as required, to prevent an over
accumulation.
Permanent press, durable press and other modern day fabrics require
the care that your laundry dryers now provide.
At the end of the drying cycle, a timed “cool-down” control
automatically takes over and continues the rotation of the fan and
basket without heat until the garment load reaches a safe cool
temperature. This function is performed at the end of each drying
cycle and continues for two minutes.
Dryers must be electrically grounded by a separate #14 or larger
green wire from the grounding terminal within the service connection
box to a cold water pipe, or through the fourth green wire properly
grounded and connected to the grounding terminal. In all cases, the