LES
4, 5, 6
- 234xxx xxxx
45 / 62
Slide plate mounting
Fig. 20 - linear unit LES 4, 5, 6 for slide plate mounting - frame
Laterally protruding carriage plates enable the guide carriages to be fixed to the frame and thus enable linear
movement of the linear guide rail relative to the frame. The fixing and positioning of these ground steel plates on
the carriages is again carried out with socket head screws - M6 and pins. End countersinks for socket head screws -
M6 enable the adaptation of the linear unit on the frame.
Mounting of optional motor modules
Direct drive modules
Fig. 21 - Mounting direct drive module
The mounting of the direct drive module to the linear units is shown in the above figure. It must be ensured that
the parts to be connected are free of burrs, rust and dirt.
Before tightening the coupling halves, make sure that the spindle and motor axis are well aligned.
The tightening torque of the clutch clamping screws is 3 Nm.