Isel LES4 - Maintenance Plan; Fig. 27 - Lubrication Points of the Linear Unit LES

Isel LES4
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LES
4, 5, 6
- 234xxx xxxx
56 / 62
Fig. 27 - Lubrication points of the linear unit LES
Proceed as follows to lubricate the linear unit LES.
1. Remove the cover caps.
2. Position the guide carriage behind a lubrication hole. (see points)
3. Place the grease gun on all accessible grease nipples and lubricate the shaft slides, guide, ball screw nut and
ball screw. 2 - 3 strokes are sufficient.
4. Push the cover caps back in.
āœ“ The ball screw nuts of the linear unit are lubricated.
7.3 Maintenance plan
Maintenance interval
Activity to be performed
on request
Cleaning the linear unit
300 - 700 Operating hours
Relubrication guide carriage and ball screw nut with special grease from isel Germany AG
monthly
- Visual inspection of linear guide rail - wear
- Visual inspection of the toothed belt (tension, abrasion...)
- Acoustic check for unusual noise
every two years
- Replacement timing belt
- Check backlash-free guide carriage and ball screw