Chapter 2 DAILY OPERATION
2.3 FIXED PRICE ITEMS
1
[Initial Display]
Press the [MODE] key.
Make sure that the initial display appears
and the ZERO indicator is lit.
Note: If the ZERO indicator is not lit, press the
[ZERO] key to turn on the indicator.
d
2
[PLU Call Up]
Key in a desired PLU number and press
the [PLU] key, or press a desired preset
PLU key.
Note: Refer to Step 2 of Section 2.2 for PLU call
up procedures.
Example: Fixed price item PLU “1”
d
3
[Automatic Label Issue]
For a fixed price item and when the machine
is in AUTO mode, key in the desired numbe
of labels to be issued and press the [PRINT]
key.
Note 1: If the number of labels to be issued has
not been keyed in, labels are issue
continuously. To stop label issue, press
the [PRINT] key again.
Note2: To eliminate the AUTO indicator, press
the [PREPACK] key.
Example: 8 labels
d
d
y
y
y
4
[Manual Label Issue]
When the machine is in MANUAL mode,
press the [PRINT] key to issue a label.
Note: In MANUAL mode, only one label is
issued.
d
2-8 BC-4000TEC User’s Manual No. JBAW97EBC-4000TEC