EasyManua.ls Logo

Ismatec ISM936 User Manual

Default Icon
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
FRANÇAISENGLISHDEUTSCH
Hochpräzise
Schlauchpumpe
mit Planetenantrieb
IPC
4 KanäleI SM930
8 KanäleI SM931
12 KanäleI SM932
16 KanäleI SM933
24 KanäleI SM934
IPC-N
4 KanäleI SM935
8 KanäleI SM936
12 KanäleI SM937
16 KanäleI SM938
24 KanäleI SM939
High precision
Tubing Pump
with planetary drive
IPC
4 Channels ISM930
8 Channels ISM931
12 Channels ISM932
16 Channels ISM933
24 Channels ISM934
IPC-N
4 Channels ISM935
8 Channels ISM936
12 Channels ISM937
16 Channels ISM938
24 Channels ISM939
Pompe
péristaltique
de haute précision, avec
entraînement planétaire
IPC
4 Canaux ISM930
8 Canaux ISM931
12 Canaux ISM932
16 Canaux ISM933
24 Canaux ISM934
IPC-N
4 Canaux ISM935
8 Canaux ISM936
12 Canaux ISM937
16 Canaux ISM938
24 Canaux ISM939
Operating Manual
Mode d‘emploiBetriebsanleitung

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Ismatec ISM936 and is the answer not in the manual?

Ismatec ISM936 Specifications

General IconGeneral
TypePeristaltic Pump
DisplayLCD
Power Supply100-240 VAC, 50/60 Hz
Communication InterfaceRS-232
WeightVaries by model

Summary

Safety Precautions

Warranty Information

Warranty Terms and Conditions

Details warranty conditions, exclusions, and claims procedures.

Operating Panel Overview

Start/Stop and Standby Functions

Details the RUN/STOP button and standby mode operation.

Operating Panel Controls

Flow Rate and Dispensing Modes

Details PUMP% Flow rate, DISP Volume, DISP Time, and PAUSE Time modes.

Basic Settings Configuration

Selecting Basic Settings Menu

Steps to enter the basic settings menu.

Pumping by Flow Rate

Flow Rate Calibration

Pumping by Drive Speed

Stand-by Mode Operation

Dispensing by Volume

Volume Calibration

Dispensing by Time

Volume Dispensing within Time Interval

Intermittent Dispensing by Volume

Intermittent Dispensing by Time

Number of Dispensing Cycles

Pumping Against Pressure

Overcurrent Protection

Analog Interface Description

Analog Interface Pin Functions

Switch Settings (S1 and S2)

DIP Switch S1 Configuration

Details the settings for DIP switch S1 for various input signals.

Sliding Switch S2 Function

Explains the function of sliding switch S2 for speed output.

Serial Interface and Addressing

Pump Address Setting

How to set the pump's serial address (1-8).

Command Structure and Syntax

Details the format and syntax of serial commands.

Serial Interface Commands

Drive Control Commands

Commands for controlling pump drive (start, stop, direction).

Serial Interface Commands - Operating Modes

Selecting Operating Modes

Commands to select pump operating modes.

Parameter Interrogation and Setting

Commands to query and set parameters.

Serial Interface Commands - Parameters

Serial Interface Commands - Volume and Cycles

Serial Interface - Inputs and Outputs

Flow Rate Data

Technical Specifications Overview

Drive and Speed Specifications

Technical details on the drive motor, speed, and rollers.

Technical Specifications - Pressure and Control

Differential Pressure and Remote Control

Specifications for differential pressure and remote control.

Mains Connection, Fuse Rating, and Power Consumption

Details mains connection, fuse rating, and power consumption.