Technical Specification
Parameter IT6018C-500-120
Read Back Temperature
Coefficient
Voltage
≤50PPM/
(of Output/+Offset)
Current ≤200PPM/
Rise Time( no load ) Voltage
≤15ms
Rise Time( full load ) Voltage
≤30ms
Fall Time( no load ) Voltage
≤30ms
Fall Time( full load ) Voltage
≤15ms
Transient Response Time Voltage
≤2ms
AC Input
Voltage
198V to 264V (Derating 50%)
342V to 528V (Three-phase four-wire)
Maximum Input
Current
33.37A
Maximum Input Ap-
parent Power
19.8kVA
Frequency
47Hz63Hz
Setup Stability-30min Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Setup stability-8h Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Readback Stability-30min Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Readback stability-8h Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Efficiency
92%
Remote Sense Compensa-
tion Voltage
≤5V
Command Response Time
2mS
Power Factor 0.99
Storage Temperature
-10℃~70
Protective Function
OVP, OCP, OPP, OTP and Vsense reversed protection
Standard Interface
Standard: USB, CAN, LAN, VCP; optional: GPIB, analog card (in-
cludes RS232), fiber optic socket
Isolation ( output to ground)
1000V
Working Temperature
050
Copyright © Itech Electronic Co., Ltd.
176

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6012C-800-50 and is the answer not in the manual?

ITech IT6012C-800-50 Specifications

General IconGeneral
BrandITech
ModelIT6012C-800-50
CategoryPower Supply
LanguageEnglish

Related product manuals