Technical Specification
Parameter IT6018C-1500-40
Setup stability-8h Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Readback Stability-30min Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Readback stability-8h Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Efficiency
92%
Remote Sense Compensa-
tion Voltage
≤15V
Command Response Time
2mS
Power Factor 0.99
Storage Temperature
-10℃~70
Protective Function
OVP, OCP, OPP, OTP and Vsense reversed protection
Standard Interface
Standard: USB, CAN, LAN, VCP; optional: GPIB, analog card (in-
cludes RS232), fiber optic socket
Isolation ( output to ground)
1800V
Working Temperature
050
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
40KG
6.1.6 2250V
6.1.6.1 IT6018C-2250-25
Parameter IT6018C-2250-25
Rated value
Output Voltage
02250V
( 0 -40 ) Output Current
-2525A
Output Power
-1800018000W
Output Resistance
0
Line Regulation Voltage
≤0.01%FS
±(of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%FS
Copyright © Itech Electronic Co., Ltd.