Power Supply Function
Select Internal List Program
You can select a List file saved inside the instrument to be in the Open state
and wait for subsequent triggers to run. The procedures are as follows:
1. Press the composite keys [Shift]+[I-set] (Function) on the front panel to en-
ter the function menu.
2. Select 1. LIST: Off and press [Enter].
3. Press the Left/Right key to select Open and press [Enter].
4. Press the Left/Right key to select Internal and press [Enter].
5. Set the name of the List file to be recalled (that is, the file name set in Edit),
and press [Enter].
The interface returns to the main interface of the LIST function, which is dis-
played as follows:
FUNCTION LIST
Run Edit Open Export
If you select Run and press [Enter], the instrument will enter LIST mode
and wait for the trigger to run.
Export List Program
Supports exporting the internal List file to an external USB flash drive. The ex-
ported List file is saved in .csv format.
1. Insert the USB flash drive into the front panel USB connector.
2. Press the composite keys [Shift]+[I-set] (Function) on the front panel to en-
ter the function menu.
3. Select 1. LIST: Off and press [Enter].
4. Press the Left/Right key to select Open and press [Enter].
5. Press the Left/Right key to select Internal and press [Enter].
6. Set the name of the List file to be recalled (that is, the file name set in Edit),
and press [Enter].
The interface returns to the main interface of the LIST function, which is dis-
played as follows:
FUNCTION LIST
Run Edit Open Export
7. Press the Left/Right key to select Export and press [Enter].
8. Press the Left/Right key to select Yes and press [Enter].