IT6700 User manual 
User Manual 
27
SN-1 XXXXXX 
the first six number of SN 
SN-2 XXXXXX 
the middle six number of SN 
SN-3 XXXXXX 
the last six number of SN 
EXIT 
Exit the information menu 
EXIT MENU 
Exit the main menu 
 
 
Note:Pressing 
ESC
button can enable you to quit any function setting. 
 
 
5.9.2  Menu functions  
Maximum voltage set(MAX VOLT) 
The range of setting voltage is from 0V to rated voltage. You can press 
(Shift)+
I-setI-set
(Menu) button to enter the menu, then press  、 key to select >MAX 
VOLT item. Press 
Enter
  button to confirm. After you set the max voltage value, the output 
voltage value can only be set within the max voltage. The default max voltage value is the 
rated value.   
 
 
Over current protection set(OCP SET) 
Over current protection feature allows the user to set an over current protection point, when 
the current in the circuit is larger than the current protection point, the power supply will 
enter OCP protection. Over current protection, power output will be off, and accompanied by 
the chirping of the buzzer, the VFD mark Prot will be lit, and the emergence of "OVER 
CURR" alarm 
The operation to set the OCP point:   
Press
(Shift)+
I-setI-set
(Menu)button to menu, press  、  to overturn to OCP SET  ,
press
Enter
button,and  、 to select ON,press
Enter
  to confirm, set OCP point by 
pressing numeric keys,    then press 
Enter
. At last, press    to escape.   
 
Power-on parameters set (P-MEM) 
 
This item can set power on parameters. If you select RESET item, then all the 
parameters will be initialized to the factory setting. Output voltage and current will always be 
0V/max rated current; if set to Keep, the output value will be the same with last power off 
state. The default setting is RESET item. 
 
  Power On Output State(P-OUT )       
This item can set the power on output state. If you select KEEP item, that indicates the 
power on output state is the same with output state before this item is set. If you select Off 
item, unit will automatically in off mode when you power on. Default setting is Off item.  
Esc
Esc