Function and Features
Copyright © Itech Electronics Co., Ltd. 28
5. Set the first step voltage and press to confirm.
LIST VOLTAGE
Step 0 Voltage=0.0
V
6. Set the first step frequency and press to confirm.
LIST FREQUENCY
Step 0 Frequency=50.0
Hz
7. Set the slope(0.1~999.9),press to confirm.
LIST SLOPE
Step 0 Slope=0.0
S
8. Set the time unit:S,min,hour,press to confirm.
DWELL UNIT
Second Minute Hour
9. Set delay time(0.1~999.9),press to confirm.
LIST DWELL
Step 0 Dwell=0.0
S
10. Disable or enable the surges or trap state,press to confirm.If
select Disable,then do nothing for step11-step14.
SD STATE
Disable Enable
11.
Press left/right key to set whether create surges/wave traps
continouly.If select Yes,power supply will create surges/wave traps in
at intervals of 100ms.Press to confirm.
SD CONTINUE
No Yes
12.
Press numeric keys to set voltage of surges/wave traps,press
to confirm.If set voltage is higher than current working
voltage,then it is surges,or it is wave traps.
SD VOLTAGE
Step 0 Voltage=0.0
V
13. Set the starting time of surges/wavetraps,press to
confirm.With the restriction of frequency,the max settable time is
25ms.
SD SITE
Step 0 Site= 0
ms
14. Set the duration time of surges/wave traps.Press to confirm.
SD TIME
Step 0 Time=0
ms
15. Repeat step4-13.
LIST VOLTAGE
Step 1 Voltage=0
V
16. NO:Do not save the list file,after power off the unit,current file will
lose.Yes:Save list file to assigned memory room for quickly recall at
any time.
LIST SAVE
No Yes
17. Store file to specified storage space(0~9 groups),press to
confirm.VFD will display “Save data success!”
LIST SAVE
Save data bank=0