Model | IT7915P-350-90 |
---|---|
Category | Power Supply |
Output Voltage | 0-350V |
Output Current | 0-90A |
Cooling Method | Forced air cooling |
Operating Temperature | 0°C to 40°C |
Storage Temperature | -20°C to 70°C |
Input Frequency | 47Hz~63Hz |
Protection Features | OVP, OCP, OTP |
Sign denotes a hazard, warns of potential personal injury or death.
Details the procedures and precautions for connecting the power cord to the instrument.
Explains how to connect test lines for measuring and testing the DUT.
Explains the procedure for powering on the instrument and initial self-test.
Describes the main interface and display elements of the IT7900P power supply.
Details how to program output voltage, frequency, and other parameters within specification ranges.
Explains how to turn the output on and off using the front panel controls.
Details how to set and manage current and power limits for output control.
Outlines the available protection functions including overcurrent, voltage limit, and over-temperature.
Introduces the anti-islanding test mode for simulating grid status and verifying protection response.
Explains how to create, edit, import, and export list files for automated testing sequences.
Details how to simulate abnormal voltage fluctuations (surge/sag) for DUT testing.
Covers methods for achieving multi-phase output using digital IO or system bus interfaces.
Guides on selecting single-phase, three-phase, or reverse-phase modes for operation.
Explains how to set the instrument's input mode to AC or DC based on application needs.
Details the AC electronic load simulation capabilities and available running modes.
Details the configuration options for Source and Load modes, including parameters and ranges.
Lists the primary technical specifications including input/output parameters, ranges, and accuracy.