Technical Specifications
Copyright ©ITECH Electronic Co., Ltd. 136
reverse phase
22334
Ω
Resolution
0.001
Ω
*8
Accuracy
0.4%+0.4%F.S.
Ω
Circuit Emulation(CE)
Ls Range
1phase
0 ~ 9999
u
H
3phase
0 ~ 9999
Rs Range
1phase
0 ~ 9.999
Ω
3phase
0 ~ 9.999
C Range
1phase
100 ~ 9999
u
F
3phase
100 ~ 9999
RL Range
1phase
0.34389
Ω
3phase
11167
Phase Range
Range
Rectified Mode *9
-82.8º~+82.8º
°
-90º~+90º
(Current Source
Mode:
+90.01º~+180º & -90.01º~-180º)
Resolution
0.01
°
Accuracy
1% F.S.
°
CF
Range
1.414 ~ 5.0
Resolution
0.001
DC
Mode
Voltage Range
30 ~ 499
V
Current Range
1phase
090
A
Current Slope
200
us
Running Mode
CC, CV, CR, CP
Measurement parameterSource
Voltage
RMS
Resolution
0.01
V
Accuracy
DC,16Hz500Hz
0.1%+0.1% F.S.
500.01Hz1.4kHz
0.1%+(0.2%*kHz) F.S
Temperature
coefficient
< 100ppm/ F.S.
Current
RMS
Resolution
0.01
A
Accuracy
DC,16Hz150Hz
0.1% + 0.2% F.S.
150.01Hz500Hz
0.2% + 0.3% F.S.
500.01Hz1.4kHz
0.3% + (0.6%*kHz)
F.S
Temperature
coefficient
< 200ppm/ F.S.
Peak
current
Resolution
0.1
A
Accuracy
DC,16Hz500Hz
0.4% + 0.6% F.S.
500.01Hz1.4kHz
0.4% + (1.2%*kHz)
F.S
Output power
Resolution
0.001
kW
Accuracy
DC,16Hz500Hz
0.4% +0.4% F.S.
500.01Hz1.4kHz
0.4% +(0.8%*kHz)
F.S
Harmonic
measurement
Max.
50/60Hz
up to 50
orders
Measurement parameterLoad
Voltage
RMS
Range
0350
Vrms
Resolution
0.01
V
Accuracy
DC,30Hz500Hz
0.1%+0.1% F.S.
Temperature
coefficient
< 100ppm/ F.S.
Current RMS
Range
090
A
Resolution
0.01
A