Quick Start 
  Copyright ©  Itech Electronic Co., Ltd.  18 
  To avoid burning out, pay attention to marks of positive and negative 
polarities before wiring. 
Selftest steps 
Normal selftest procedures: 
1.  Correctly connect the power cord. Press [ Power ] key to start up. 
2.  After selftest, VFD display information below. 
 
 
 
 
 
Information description: 
  The first line display actual voltage and current value. 
  The  second  line  display  the  actual  power  value  and  the  setting 
current/voltage/power/resistance value. 
  The third line display the input state/operation mode. 
3.  Press [Shift] + [7], VFD display products information. You can press 
direction buttons to examine product’s model/SN/software version. 
Error Information References 
The following error information may occur when an error occurs during Power 
On self-test: 
  If the EEPROM was damaged, the VFD will display “Eeprom Fail”. 
  If the latest operation data in EEPROM is lost, then VFD will display 
“Config Data Lost”. 
  If the calibration data in EEPROM is lost, then VFD will display “Cal data 
lost”. 
  If the system setting data in EEPROM is lost, the VFD will display “Eeprom 
data lost”. Please press [Shift] + [4] and [0] to save after setting 
parameters.   
Exception handling 
If the electronic load cannot start normally, please check and take measures by 
reference to steps below. 
1.  Check whether the power line is correctly connected and confirm whether 
the electronic load is powered. 
Correct wiring of power line => 2 
Incorrect  wiring  of  power  line  =>  Re-connect the  power  line  and  check 
whether the exception is removed. 
2.  Check  whether  the  power  in  On.  [Power]  key  is  under  “ ”(On) 
status. 
Yes => 3 
No => Please check the [Power] key to start power and check whether the 
exception is removed. 
3.  Check whether the power voltage setting of the electronic load is larger 
than the power supply voltage. If the power voltage of the load is set to 
220V and the supply voltage is 110V, the electronic load will not start. 
4.  Check whether the fuse of electronic load is burned out. 
If yes, change fuse. Detailed steps: 
  Pull out power line and take out the fuse box at power line jack with a 
small screw driver. As shown below.