EasyManua.ls Logo

JAC ECO+ - Error Codes; Error Code Reference

JAC ECO+
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English
16
11 ERROR CODES
Should the problem persist, please contact your technician.
Flashes or code displayed on
screen
Problem description
Action
2
Cut-out SECU1 tripped during cycle.
Please restart the
machine using the
emergency stop (fig.1,
n°10). Should the
problem persist, please
contact your technician.
3
Current to upper actuator (M2) in excess of
6 A for 1 second, during advance/cut.
4
Cut motor thermal cut-out (F3) tripped.
5
No actuator (M2) movement despite tension set
to maximum.
6
Loaf pusher not in initial position. Limit switch S1
not tripped.
7
Advance/cut cycle time in excess of 60 seconds.
8
Return cycle time in excess of 30 seconds.
9
Rear (S1) and front (S2) limit switches tripped at
the same time.
10
Current to upper actuator (M2) in excess of 5 A
for 1 second during carriage return.
11
Front safety cover (S3) open in the course of a
cycle.

Table of Contents