INSTALLATION/OPERATION &
TECHNICAL MANUAL
FOR JACKSON MODELS:
CONSERVER XL, CONSERVER XL2
CONSERVER XL2-CML, CONSERVER XL2-CMR
CONSERVER AXL, CONSERVER AXL2
CONSERVER AXL2-CML, CONSERVER AXL2-CMR
Jackson MSC, LLC.
P.O. BOX 1060
HWY. 25E
BARBOURVILLE, KY. 40906
FAX (606) 523-9196
PHONE (606) 523-9795
www.jacksonmsc.com
CHEMICAL SANITIZING, SINGLE AND DUAL RACK
UPRIGHT DOOR DISHMACHINES
September 22, 2009
P/N 7610-002-10-23 (Revision I)

Table of Contents

Other manuals for Jackson CONSERVER XL

Questions and Answers

  • A
    Amanda HenrySep 9, 2025
    How to troubleshoot a Jackson Laboratory Equipment sanitizer pump that doesn't run?
    • R
      Robert CruzSep 9, 2025
      If the sanitizer pump on your Jackson Laboratory Equipment doesn't run during the cycle or when using the prime switch, check for a loose motor terminal wire and tighten the connections. If the connections are secure, the sanitizer pump motor might be faulty. If you read 120V at the sanitizer motor terminals during the sanitizer feed cycle, replace the motor.
  • L
    ldavisSep 8, 2025
    What to do if Jackson Laboratory Equipment machine will not run in 'ON' position or in Delime mode?
    • A
      alexandriagriffinSep 8, 2025
      If your Jackson Laboratory Equipment machine won't run in either the 'ON' position or in Delime mode, a faulty OFF/ON/FILL switch could be the cause. With the switch ON, check the voltage between the BLACK and WHITE/BLACK wires on the switch and replace it if you find 120V. Alternatively, a faulty NORMAL/DELIME switch might be the problem; in the NORMAL position, check the voltage between the WHITE/BLACK & WHITE/RED wires to the switch and replace it if you find 120V.
  • S
    Sarah GardnerSep 6, 2025
    Why is the wash motor running continuously on my Jackson CONSERVER XL Laboratory Equipment?
    • C
      christiancookSep 7, 2025
      If the wash motor is running continuously on your Jackson Laboratory Equipment, first check if the NORMAL/DELIME switch is in the Delime position and place it in the Normal position. Another cause could be that the wash relay contacts are welded closed; turn the machine off, and if the wash relay doesn't release, replace the contactor. Additionally, the cam timer might be stalled in the wash or rinse cycle; if the cam timer isn't rotating, check the voltage to the timer motor, and if there's no voltage when the door is closed, check the wires and/or replace the motor. Lastly, a faulty wash motor microswitch could be the issue; tighten connections, make sure the switch makes contact, and replace it if necessary.
  • T
    Timothy CarterSep 2, 2025
    What causes a Jackson CONSERVER XL Laboratory Equipment machine to fill continuously even with no power?
    • R
      Richard RogersSep 2, 2025
      If your Jackson Laboratory Equipment machine fills continuously even when no power is applied, the solenoid valve is likely dirty or faulty. Try cleaning the valve, and if that doesn't work, replace the plunger and/or diaphragm.
  • M
    Mathew HudsonSep 1, 2025
    What to do if Jackson Laboratory Equipment machine will not run, no voltage at wash relay terminals L1 and T1?
    • J
      Jose CastilloSep 1, 2025
      If your Jackson Laboratory Equipment dishmachine won't run and there's no voltage at the wash relay terminals L1 and T1, first ensure the service disconnect switch is on. If it is faulty, turn disconnect on. Also, check if the branch circuit breaker has tripped or a fuse has blown; reset or replace as needed. Finally, inspect for loose or broken connections to the dishmachine and tighten or replace them.
  • M
    Matthew HooverAug 30, 2025
    How to troubleshoot a Jackson Laboratory Equipment wash motor that does not run?
    • M
      Michele FarleyAug 30, 2025
      If the wash motor in your Jackson Laboratory Equipment doesn't run unless the wash relay is manually depressed, but other functions work, a faulty control relay could be the cause. Check the voltage across relay contacts #7 & #4; if it reads 120V during the wash cycle, replace the relay. Another possibility is a faulty wash relay. Check voltage at relay coil between ORANGE/BLACK and WHITE wires. If you read 120V, coil is faulty. Replace the relay.
  • B
    Brittany BridgesAug 29, 2025
    Why is my Jackson Laboratory Equipment machine cycling continuously?
    • T
      Thomas SmithAug 29, 2025
      If your Jackson Laboratory Equipment machine is cycling continuously, the cycle reset switch might be loose; try repositioning the switch assembly and bending the metal lever if necessary. Alternatively, the cycle reset switch could be faulty; measure between the BLACK/YELLOW & ORANGE wires on 'cycle reset' switch while timer is rotating. As the switch lever drops into home position you should measure 120V. If not, adjust or replace the switch.
  • M
    Matthew ClarkAug 27, 2025
    How to resolve low pumped water pressure in Jackson CONSERVER XL?
    • P
      Patrick SmithAug 27, 2025
      If you're experiencing low pumped water pressure in your Jackson Laboratory Equipment, it could be due to an obstruction in the pump housing or wash manifold; disassemble and clear any blockages. Alternatively, the pump impeller might be worn or broken, requiring replacement.