B
LDU ERROR CODES
en-103
Safety, Operation, & Maintenance Manual
Lithium
Curr Meas When Off Ch6:
More than 200 mA of current is
detected when the output should be
off.
Load Active When ODO Off Ch1:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
Load Active When Off ODO Ch2:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
Load Active When Off ODO Ch3:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
High Side Short Circuit:
A hardware short circuit is detected.
Disabling of the output is required to
clear the fault.
High Side Input Low:
The system detected that the high
side input is low. This indicates that
the high side input is not connected
or has a short circuit to B-.
LDU Error Code Description
Caution
LED
Alarm
Sound-
ing
Engine
Stop
Traction
Stop
Mow Stop
On Off Yes No Yes No Yes No Yes No