EasyManua.ls Logo

Jacobsen ECLIPSE 360 - Page 106

Jacobsen ECLIPSE 360
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B
en-106
Safety, Operation, & Maintenance Manual
LDU ERROR CODES
Lithium
Checksum Error on Can’t Talk:
The system has detected a
checksum error on a can’t talk
EEPROM segment.
EEPROM Size Error:
The system has detected an
EEPROM memory size mismatch.
Load Active When HS Off Ch1:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
Load Active When HS Off Ch2:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
Load Active When HS Off Ch3:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
Startup Sequence Error:
There was an error in the startup
sequence of the application.
Startup Calibration Timeout:
A startup calibration of position has
timed out.
Vehicle Speed Start Timeout:
The reception of the first vehicle
speed frame has timed out.
LDU Error Code Description
Caution
LED
Alarm
Sound-
ing
Engine
Stop
Traction
Stop
Mow Stop
On Off Yes No Yes No Yes No Yes No
TRACTION
FAULT 5524
STEERING
FAULT 5524
3WD TRACTION
FAULT 5524
TRACTION
FAULT 5530
3WD TRACTION
FAULT 5530
TRACTION
FAULT 5541
3WD TRACTION
FAULT 5541
TRACTION
FAULT 5542
3WD TRACTION
FAULT 5542
TRACTION
FAULT 5543
3WD TRACTION
FAULT 5543
STEERING
FAULT 6001
STEERING
FAULT 6002
STEERING
FAULT 6100

Table of Contents