LDU ERROR CODES
Lithium
Checksum Error on Can’t Talk:
The system has detected a
checksum error on a can’t talk
EEPROM segment.
EEPROM Size Error:
The system has detected an
EEPROM memory size mismatch.
Load Active When HS Off Ch1:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
Load Active When HS Off Ch2:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
Load Active When HS Off Ch3:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
Startup Sequence Error:
There was an error in the startup
sequence of the application.
Startup Calibration Timeout:
A startup calibration of position has
timed out.
Vehicle Speed Start Timeout:
The reception of the first vehicle
speed frame has timed out.
LDU Error Code Description
Caution
LED
Alarm
Sound-
ing
Engine
Stop
Traction
Stop
Mow Stop
On Off Yes No Yes No Yes No Yes No