B
en-126
Safety, Operation, & Maintenance Manual
LDU ERROR CODES
Lithium
CRC Error:
The system has received a message
with a CRC error.
Sequence Error:
CRC Error:
The system has received a message
with a sequence number error.
Rx Timeout:
CRC Error:
The system did not receive a
message within the time limit.
Bad Function Argument:
An internal communication API
function was called with wrong
arguments.
Inv State Change:
The two CPU device state machines
are not in synchronization.
Tx Overflow:
An attempt to send an internal
message failed due to no room in
FIFO.
Unknown Rx Frame:
An internal communication message
was received with unknown
information.
CMD Busy:
An attempt was made to issue a new
command before a previous
command has finished.
Pro Ver Mismatch:
The internal communication
revisions in the two CPUs are not
compatible.
Vehicle Speed Start Timeout:
The reception of the first vehicle
speed frame has timed out.
LDU Error Code Description
Caution
LED
Alarm
Sound-
ing
Engine
Stop
Traction
Stop
Mow Stop
On Off Yes No Yes No Yes No Yes No
STEERING
FAULT F010
STEERING
FAULT F011
STEERING
FAULT F012
STEERING
FAULT F013
STEERING
FAULT F014
STEERING
FAULT F015
STEERING
FAULT F016
STEERING
FAULT F017
STEERING
FAULT F018
STEERING
FAULT F020