EasyManuals Logo

Jacobsen ECLIPSE 360 User Manual

Jacobsen ECLIPSE 360
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
B
en-94
Safety, Operation, & Maintenance Manual
LDU ERROR CODES
Lithium
Phase UW Not Connected:
A startup check of the motor connec-
tions measured current i phase U to
be under the defined limit.
Phase VW Not Connected:
A startup check of the motor connec-
tions measured current i phase V to
be under the defined limit.
Drive Not Disable:
A startup check of the motor connec-
tions detected that the drive is not dis-
abled.
Rotor Rotation Too High:
A startup check of the motor connec-
tions detected that the rotor rotation is
too high.
Hardware detected short circuit in
controller, cabling to motor or in
motor. Shut mower off, then restart. If
fault returns, mower must be towed
back to maintenance shed.
Short Circuit Glitch:
The system has detected a short
circuit in the hardware. Shut mower
off, then restart. If fault returns,
mower must be towed back to
maintenance shed.
LDU Error Code Description
Caution
LED
Alarm
Sound-
ing
Engine
Stop
Traction
Stop
Mow Stop
On Off Yes No Yes No Yes No Yes No
TRACTION
FAULT 2317
3WD TRACTION
FAULT 2317
TRACTION
FAULT 2318
3WD TRACTION
FAULT 2318
TRACTION
FAULT 2319
3WD TRACTION
FAULT 2319
TRACTION
FAULT 2320
3WD TRACTION
FAULT 2320
TRACTION
FAULT 2340
STEERING
FAULT 2340
3WD TRACTION
FAULT 2340
TRACTION
FAULT 2341
STEERING
FAULT 2341
3WD TRACTION
FAULT 2341