J-200
13.3  CLEARRAY® System
Your new hot tub has the CLEARRAY unit installed.  
The CLEARRAY System is an exclusive technology utilizing 
ultraviolet light to help keep your water clean*. The ballast is 
the power supply for the CLEARRAY unit; it has two LED 
indicator lights, the green indicating incoming power ow and the 
red indicating the system is properly working. CLEARRAY is 
standard for all models. 
Note: The CLEARRAY only runs when pump 1 is on low speed 
for an automatic function, a heat call or a lter cycle.
After a year the bulb must be replaced. A message will appear on the 
LCD display when the time allotted has expired. In order to clear the 
message, a new UV bulb needs to be installed and the timer must be 
reset, page (page 38).
Note: In order to access the CLEARRAY unit the front synthetic panel 
must be removed.
*Clean is dened as the removal of microscopic (to 30 µm level) debris 
from the water. Ozone aids in the grouping of small debris. Once 
combined, the debris can be more easily caught by the ltration process.
WARNING!
DO NOT LOOK AT LIT BULB
SEVERE EYE DAMAGE
OR BLINDNESS CAN OCCUR
1
2
0
 
- 
230
V
WARNINGS:
•  Do not operate the UV-C emitter when it is removed from the 
appliance enclosure.
•  This appliance contains a UV-C emitter.
•  Unintended use of the appliance or damage to the housing may 
result in the escape of dangerous UV-C radiation. UV-C radiation 
may, even in little doses, cause harm to the eyes and skin.
•  Appliances that are obviously damaged must not be operated.
•  Read the maintenance instructions before opening the appliance.
!
47