EasyManuals Logo

Jacuzzi J-385 User Manual

Jacuzzi J-385
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
21
J-300
5. Add Start-Up Chemicals
Add the spa water chemicals as recommended by your authorized
Jacuzzi dealer. See “Water Quality Maintenance” (page 46) for general
guidance.
WARNING: RISK OF POISONING OR DEATH.
Never leave chemicals opened and accessible to anyone. Use
chemicals according to the vendors instructions. Always store
chemicals in a safe and/or locked location. Keep away from
and out of reach of children.
!
6. Establish A Stable Sanitizer Reading
Establish a stable sanitizer reading of no less than 1.0 ppm free chlorine
or 2.0 ppm bromine. To ensure healthy water conditions, always maintain
a constant sanitizer reading within the levels recommended on the inside
cover of this manual. If sanitizer levels cannot be stabilized, perform the
decontamination procedure steps 9-15 on the following page.
Note: The “decontamination procedure” steps 9-16 should also be used
after the spa has been “Winterized” (page 45) or has been sitting with-
out power for an extended period.
7. Set Spa To Heat
To warm spa water to a comfortable temperature, follow these
steps:
The LCD display on the control panel displays the actual
temperature of the spa water. Press either the COOLER ( ) or
WARMER ( ) button once to display the “set” temperature for 5
seconds. If you want the water to heat to a different temperature,
simply press COOLER ( ) or WARMER ( ) within 5 seconds.
The set temperature increases or decreases by one degree each
time one of these buttons is pressed.
The heater will turn off when the temperature corresponding to the
thermostat setting is achieved.
To access the overtemp feature refer to Section 10.3, page 28.
Important Heater Details:
The maximum water temperature setting for your spa is 104°F
(40°C) and the minimum setting is 65°F (18°C).
For North American spas connected to a 40 amp service, jets pump
#1 and jets pump #2 must be turned off to operate the heater.
For Export spas connected to a 20 amp service, jets pump #1 and
jets pump #2 must be turned off to operate the heater.
Setting the thermostat at maximum will not accelerate the heating
process. This will only result in a higher ultimate temperature.
The heater operates until the water reaches the programmed “set
temperature,” then turns off. The heater will reactivate after the
water cools to approximately 2° below the set temperature.

Table of Contents

Other manuals for Jacuzzi J-385

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi J-385 and is the answer not in the manual?

Jacuzzi J-385 Specifications

General IconGeneral
Seating Capacity6-7 Adults
Pumps2
Circulation PumpYes
Primary Pump2.5 HP
Secondary Pump2.5 HP continuous duty, 4.8 HP breakdown torque
Electrical Requirements240V