EasyManuals Logo

Jacuzzi JVS165S User Manual

Jacuzzi JVS165S
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
Page 18 of 32 IS2303VSP3J Rev-A
Fill strainer housing with water to suction pipe level. If water leakage occurs from anywhere on the pump or filter, DO
NOT start the pump. If no leakage occurs, stand at least 10 feet from pump and/or filter and proceed with starting the
pump.
WARNING Return to filter to close filter manual air relief valve when a steady stream of water (not air or
air and water) is discharged from valve. Failure to do so could result in severe personal injury.
ATTENTION NEVER OPERATE THE PUMP WITHOUT WATER. Water acts as a coolant and
lubricant for the mechanical shaft seal. NEVER run pump dry. Running pump dry may damage seals, causing leakage,
flooding, and voids warranty. Fill strainer housing with water before starting motor.
ATTENTION Do NOT add chemicals to pool/spa system directly in front of pump suction. Adding
undiluted chemicals may damage pump and voids warranty.
ATTENTION Before removing strainer cover:
1. STOP PUMP before proceeding.
2. CLOSE VALVES in suction and outlet pipes.
3. RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve. See filter owner’s manual for
more details.
4. Remove strainer cover and fill strainer housing with water.
5. Clean and lubricate strainer cover O-ring with "Jack's 327" if necessary.
6. Replace strainer cover on strainer housing.
7. OPEN VALVES in suction and outlet pipes.
Note: Tighten strainer cover lock ring by hand only (no wrenches).
Turn on power and wait for pump to prime, which can take up to ten (10) minutes. Priming time will depend on vertical
length of suction lift and horizontal length of suction pipe. If pump does NOT prime within 10 minutes, stop motor and
determine cause. Be sure all suction and discharge valves are open when pump is running. See Troubleshooting Guide.
6.3. User Interface Summary
Figure 6.3-1
1. Preset Speeds: Buttons labeled SPEED 1 thru SPEED 4 can be used to run the pump at a predetermined speed until
the next programmed timer is scheduled to begin. Preset Speed settings can be quickly updated using the + and -
arrow buttons to change the speed and then pressing the > button to save the new speed setting if desired.
a. Default Speeds:
Speed 1: 1150 rpm

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi JVS165S and is the answer not in the manual?

Jacuzzi JVS165S Specifications

General IconGeneral
BrandJacuzzi
ModelJVS165S
CategoryPlumbing Product
LanguageEnglish

Related product manuals